11/17
Check the precision of the connections in the system!
The +14V , GND , CD , GNV and Uv signals are common to all components of the system.
The Vin and V out signals are specific to each Terminal or video camera (they are not to be
connected jointly).
Any short circuit between them leads to the non-operation of the entire system.
COMMISIONING OF THE SYSTEM
6
6.2 Checking the precision of the connections in the system and the
connection of the Supply control unit
6.1 Description of the supply control unit
TIME:
Lock timing adjustment
The Supply control unit includes:
Protection lid for the
connections
Protection lid for the
connections
Front lid
LED signaling of programming /
defect within the system
*PROG. : programming button
S2:
existence of tension at the
+Uv - GND terminals
S1:
presence of tension at the
+14V - GND terminals
*The kit does not require programming. This button is used only if you add additional Terminals or
panels to the system.
GND
LA
AUX 2
AUX 1
Automation
Relay contact
Maximum switched current
: 1.5 A
5
.
2
Auxiliary command connection (opt
ional
)
5.1 Installation of the electromagnetic lock
Direct current (DC)
Direct current
electromagnetic lock (DC)
LC2
C
abl
e
2 x 0.75 mm
²
BUT
LC
LA/C
LA
Supply control unit
LC1
C
abl
e
2 x 0.75 mm
²
Alternative current
electromagnetic
lock (AC)
BUT
LC
LA/C
LA
Transformer
12 V
230 V
AC
Supply control unit
Alternative current (AC)
The Supply control unit can supply a current of
max. 1A for the supply of the lock.
The tension of +14 V DC is present on the LC
terminal of the Supply control unit.
The connection of a lock actuating button from the
interior of the building will be made at the BUT
and LC terminals of the Supply control unit.
(opt
ional
)
AC