background image

bell

issimo

 2-72 Way Video Entry System 

PD-098 Issue 4B 

Installation and Operating Manual 

Page 29 of 44 

Diagram B – Large system Overview 

Illustration of Power Supply Distribution

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PSU

PS4

12V

PSU

PS4

12V

PSU

PS4

12V

Door

Panel

Door

Panel

Door

Panel

Further

Entrances

Further

Controllers

Cat5

Cat5

Cat5

Cat5

Cat5

Cat5

Cat5

BSC4 Video

 Controller

2 x

1mm²

Input

Passthru

Input

Passthru

Input

Passthru

Input

Passthru

Output

Input

Output

Input

Output

Input

2 x 1mm²

2 x 1mm²

2 x 1mm²

2 x 1mm²

BSC4 Video

 Controller

BSC4 Video

 Controller

BSC4 Video

 Controller

BSD8 (2-8 way)

BSD72 (9-72 way)

Door Controller

BSD8 (2-8 way)

BSD72 (9-72 way)

Door Controller

BSD8 (2-8 way)

BSD72 (9-72 way)

Door Controller

Summary of Contents for bellissimo

Page 1: ...o Video Door Entry System 2 72 Way Installation Operation Manual This manual applies to the following BSD8 72 2 to 72 Way Door Controller Version 2 Build 6 onward BSC4 Video Controller Version 2 Build 4 onward BS Colour Videophone Version 3 BSA Audio Phone Version 1 ...

Page 2: ...bellissimo 2 72 Way Video Entry System PD 098 Issue 4B Installation and Operating Manual Page 2 of 44 ...

Page 3: ...NTROLLER JUMPER SETTINGS 19 BSC4 VIDEO CONTROLLER SETTINGS 20 BS VIDEOPHONE SWITCH SETTINGS 22 TROUBLESHOOTING 23 QUICK FAULT REFERENCE 23 SPECIFICATIONS 26 DIAGRAM A 2 72 WAY BASIC SYSTEM OVERVIEW CABLING 28 DIAGRAM B LARGE SYSTEM OVERVIEW 29 DIAGRAM C BSD8 PCB DETAIL 30 DIAGRAM D 2 72 WAY BASIC SYSTEM WIRING DETAIL 31 DIAGRAM E 2 72 WAY MULTIPLE ENTRANCE WIRING DETAIL 32 DIAGRAM F EXTENSION VIDE...

Page 4: ...ices For buildings requiring a single push button at the entrance such as houses individual flats and offices please refer to the bellissimo 1 way Video Entry System manual For a digital panel with display refer to the bellissimo Digital System The bellissimo 2 72 way system is supplied with a dedicated door controller for each entrance and a video controller for every four videophones The basic s...

Page 5: ...nstallation and Operating Manual Page 5 of 44 bellissimo Colour Videophone Button Lamp Steady Flashing Mute On Off Red Videophone is muted Videophone is off hook View Camera select Amber Call in progress Ringing Lock Green Door is open Press to release lock ...

Page 6: ...ound in the videophone when they do not wish to be disturbed Call mute is activated by pressing the mute button on the videophone which then illuminates in red as a reminder The handset must be on the hook for this to work Pressing the mute button a second time will disengage the mute function During installation it is possible to set a time limit for the mute function in various values from 2 min...

Page 7: ...cally only the master unit will display a picture while ringing Once the master or extension videophone is picked up the picture will display on that unit alone Lock Type The door controller supports both fail secure and fail safe locks including magnetic locks of up to 1A rating The lock time may be set between 3 and 20 seconds See Lock Operating time and Lock Type on page 18 Exit Button and Fire...

Page 8: ...endently but will receive calls from the shared entrance For further details see the bellissimo and Bellcall Manual Gate and Block PD 120 Door Bell The BS Videophone has an input which can be used with a doorbell button or other volt free contact to ring the phone This feature is intended to replace a separate doorbell The ring is 2 seconds and all three indicators flash together Slave Output The ...

Page 9: ...BS22 Twenty two way bellissimo Video Kit comprises the following Model No Description 22 x BS Videophone 1 x BSP22 VR Vandal resistant panel with a speech unit and camera 1 x BSD72 Door controller 6 x BSC4 Video controller 2 x PS4 4A 12V power supply 1 x 203 Fail secure lock release For a bellini style kit order as BLV2 through BLV8 N B bellini systems do not include a 203 lock release Options The...

Page 10: ... and power supply ies should be wall mounted in a convenient cupboard or other protected environment with available mains power Cable length to the videophone should be less than 150m see Cable Distances page 13 In many cases the video controllers will be in the same location as the door controller s but they may be distributed as required to reduce wiring distances When placed in different locati...

Page 11: ...o account The following table is a guide to how much equipment a PS4 power supply can safely and reliably feed please contact technical support for other variations Equipment 1 x PS4 can power Comments 4 x BSC4 video controllers with 1 BS videophone per output 16 videophones directly powered Extensions may be added if separately powered by 340C s 2 x BSC4 video controllers with up to 4 BS videopho...

Page 12: ...d no shield The cores are in pairs where Blue and Blue with a White stripe are twisted together as the first pair The other three pairs are similar with main colours Orange Green and Brown Also available and acceptable are UTP Category 5e Cat5e UTP Category 6 CAT6 UTP Category 6e CAT6e The exact cable can be chosen from the above on cost and availability grounds STP Shielded Twisted Pair cables ar...

Page 13: ...pply 300m 1 x Cat5 Locally powered videophones have Auto display extensions are daisy chained 25m to 340C 1 x pair of Cat5 100m to 340C 2 x 1mm2 Door Controller to Video Controller s System Distance Cable Comments All Systems 200m 1 x Cat5 N B maximum length from any camera to any videophone to be less than 300m Panel to Door Controller System Distance Cable Comments All Systems each entrance 50m ...

Page 14: ...ight of 1 6 m measured between the ground and the centre of the camera window With flush mounting panels it is advisable to apply mastic to the top and side edges of the panel to prevent water ingress behind the panel but not to the bottom edge On construction sites the panel must be protected from corrosive substances such as brick acid The panel should be cleaned only with a damp cloth containin...

Page 15: ...lease allow a little movement on the door as operation will be impaired if fitted too tight NB Magnetic locks maglocks must be fitted with a suppressor at the lock terminals Some manufacturers fit an acceptable internal suppressor Fail Safe Exit Notes Fail safe exits require an exit button and this should be normally open so that the controller can be used to give a timed exit If the exit button h...

Page 16: ...witch can have closed contacts when the door is closed or open contacts when the door is closed the choice being made in Panel Programming The default of contacts open when door closed must be selected when this feature is not required Time Clock Sharing In a large system a single time clock can be shared between distributed equipment areas by borrowing one of the comm wires in the interconnecting...

Page 17: ...ng every 3 seconds On On Off On 10s 1 in 3 1 ring every 3 seconds On On Off Off 15s 1 in 3 1 ring every 3 seconds On Off On On 20s 1 in 3 1 ring every 3 seconds On Off On Off 30s 1 in 3 1 ring every 3 seconds On Off Off On 40s 1 in 3 1 ring every 3 seconds On Off Off Off 45s 1 in 3 1 ring every 3 seconds Off On On On 50s 1 in 3 1 ring every 3 seconds Off On On Off 60s 1 in 3 1 ring every 3 seconds...

Page 18: ...ure SW2 5 Door Status Switch Monitors doors left open Off Contacts Open when Door is Closed The default allows for no switch fitted On Contacts Closed when Door is Closed Standard normally closed switch SW2 6 Camera 2 How many cameras at this door Off Camera 1 only Default single camera per door On Enable Camera 2 Second camera at the door SW2 7 View Function Camera action when view button pressed...

Page 19: ...consult Bell System Telephones Ltd technical department at the number shown on the last page BSD8 72 Door Controller Jumper Settings Camera Terminator There is a separate jumper for both video Camera inputs This has three settings 75R for terminating coaxial cable 100R for terminating twisted pair Cat5 cable and None for use when passing the cable on to another device or controller Video Gain Cont...

Page 20: ...etting Pos Phone 1 Phone 2 Phone 3 Phone 4 0 None None None None 1 1 2 3 4 2 5 6 7 8 3 9 10 11 12 4 13 14 15 16 5 17 18 19 20 6 21 22 23 24 7 25 26 27 28 8 29 30 31 32 9 33 34 35 36 A 37 38 39 40 B 41 42 43 44 C 45 46 47 48 D 49 50 51 52 E 53 54 55 56 F 57 58 59 60 Address Offset SW7 Builds up to 6C SW7 is a 4 bit switch that is used to increase the addressing range For each bit that is switched O...

Page 21: ...ressing above 6413 For instance by making the jumper add 5000 the BSC4 would be able to address from 1 to 3210 and 5001 to 8210 Phone 1 output Extended Addressing Jumper PROG pins 2 3 Build 7A This jumper adds nn00 to the phone 1 address set using SW6 and SW7 The value nn00 is shown on the build label The jumper is stored on pins 4 5 The use of this jumper precludes the use of Odd Even addressing ...

Page 22: ...by touching the symbol again Individual Functions Settings 5 8 SW 5 Master Extension Which Videophone to set Off Master Only or first apartment station per BSC4 output On Extension Slave Second and subsequent videophones per BSC4 output SW 6 Auto Display on Ring Videophone display behaviour Off Display during ring Picture is on while ringing stays on when answered On No display during ring Picture...

Page 23: ...ble fault Power Problems Videophone resetting The three indicators lights show the power on sequence Power supply intermittent short or overload More than 1 extension enabled for auto display Lock output short circuit see Lock Problems 28V LED does not light on controller Temporarily remove connection to 28V output If it now comes on there is a short on the phone cabling 12V input connections are ...

Page 24: ...ressing the lock button instead of replacing the handset will cause the Status LED to light and after 3S all the LED s will go off If this sequence works repeatedly then the A and B data connections are probably OK and the 28V and 0V must also be OK The test also shows that the BSC4 software is running and diagnostics can now focus on the door controller to video controller wiring If it fails a vi...

Page 25: ...ed Entrance cannot be seen at night Power not connected to camera IR night illumination Connect 1 to on camera Speech Problems Loud tone at the entrance speaker Acoustic feedback Volume controls set too high Broken Audio 1 or 2 wire in the cabling Intermittent or broken wire in Data A or B Videophone has reset see the power faults table Check model 61 is hard against the panel with no gaps Check m...

Page 26: ...s 100mm Viewing Angle 92º typical Video Output PAL composite video 1Vpk pk 75 Ohm Resolution More than 330 lines Back light compensation Yes BSC4 Video Controller Size 185mm x 230mm x 42mm Supply Voltage 10 8V min 13 8V typical 15V max Current Consumption 350mA idle 3A max 13 8V BS Colour Videophone Size 180mm x 225mm x 60mm Fixing Wall Mounted Supply Voltage 11V minimum local power supply only 20...

Page 27: ... Min 13 8V Nom 14 1V Max Output Current 1A continuous 1 5A peak 5 minutes max Mains Supply Internal Fuse Not user replaceable Supply Voltage 230V 50Hz nominal Temperature Range 0 ºC to 50 ºC 840 Power Supply Battery Backed Size 350mm x 330mm x 80mm Output Voltage regulated 13 5V Min 13 8V Nom 14 1V Max Output Current 3A continuous 4A peak 5 minutes max Mains Supply Internal Fuse T2A 20mm HBC HRC C...

Page 28: ...bellissimo 2 72 Way Video Entry System PD 098 Issue 4B Installation and Operating Manual Page 28 of 44 Diagram A 2 72 Way Basic System Overview Cabling ...

Page 29: ...r Panel Further Entrances Further Controllers Cat5 Cat5 Cat5 Cat5 Cat5 Cat5 Cat5 BSC4 Video Controller 2 x 1mm Input Passthru Input Passthru Input Passthru Input Passthru Output Input Output Input Output Input 2 x 1mm 2 x 1mm 2 x 1mm 2 x 1mm BSC4 Video Controller BSC4 Video Controller BSC4 Video Controller BSD8 2 8 way BSD72 9 72 way Door Controller BSD8 2 8 way BSD72 9 72 way Door Controller BSD8...

Page 30: ... Commn 12V 12V Audio Audio Door Data Data Lock Commn B2 C 4 4 bellissimo Door Controller BSD8 Door Panel Entrance Power Supply Input Output Status Lock Power Test SW3 SW2 SW1 Cam Audio Video 100 75 High 100 75 High Cam1 Cam2 4 3 2 1 0 Video Gain Label BSD8 72 Version No Build No Expansion 1 Prog The 72 way Expansion PCB not shown It simply has 8 by 8 way terminal blocks For Call Inputs 9 to 72 and...

Page 31: ...bellissimo 2 72 Way Video Entry System PD 098 Issue 4B Installation and Operating Manual Page 31 of 44 Diagram D 2 72 Way Basic System Wiring Detail ...

Page 32: ...bellissimo 2 72 Way Video Entry System PD 098 Issue 4B Installation and Operating Manual Page 32 of 44 Diagram E 2 72 Way Multiple Entrance Wiring Detail ...

Page 33: ...u with the alternate wires Note For each cable run Only one unit must be Master Recommend the first unit Auto display on one video unit only For auto display on multiple video units see next Diagram Extension video units must be daisy chain wired to preserve video quality The last or only video unit on the cable requires the Video Terminator ON all other video units must have the Video Terminator ...

Page 34: ...ideo unit is required to provide auto display then additional power supplies will be required Note For each cable run Only one unit must be Master Recommend the first unit Extension video units must be daisy chain wired to preserve video quality The last or only video unit on the cable requires the Video Terminator ON all other video units must have the Video Terminator OFF ...

Page 35: ...tacts or any other volt free contact An illuminated bell push is not catered for Auxiliary Ring Circuit Primarily included for activating third party DDA devices the auxiliary ring output consists of a pair of volt free contacts which close while the phone is ringing If the phone is muted the contacts do not close even though the phone may flash to indicate ringing The contact rating is 1A non ind...

Page 36: ...am1 Diagram I Option Details Camera Termination Options Cameras may be wired in either twisted pair or coax and shared with other equipment Time Clock Sharing A time clock can be shared between distributed equipment areas by borrowing one of the comm wires in the interconnecting Cat5 to use as the shared Time clock common The Time clock common signal is sharable across all Bell controller types 2 ...

Page 37: ...bellissimo 2 72 Way Video Entry System PD 098 Issue 4B Installation and Operating Manual Page 37 of 44 Diagram J 2 72 Way Additional DDA Wiring ...

Page 38: ...pen exit button can still be wired to the Bellcode unit in addition to the bellissimo wiring Note 2 A 12V connection will be required if the 2 units are not sharing a power supply Connecting a Bell PAX1 Proximity Reader Connect the lock release as per this manual Leave the Proximity Reader set to fail secure the BSD controller sets the lock type Note 1 A normally open exit button can still be wire...

Page 39: ...als 2 Leave the BSD controller set to Fail Secure regardless of the type of release used 3 A normally open exit button can still be fitted to the ACT controller in addition to the bellissimo wiring 4 If the 2 units are not sharing a power supply then a connection from BSD controller 12V to ACT 0V will be required 5 Look for the notes on the ACT installation diagram concerning the use of links when...

Page 40: ...bellissimo 2 72 Way Video Entry System PD 098 Issue 4B Installation and Operating Manual Page 40 of 44 ...

Page 41: ...bellissimo 2 72 Way Video Entry System PD 098 Issue 4B Installation and Operating Manual Page 41 of 44 ...

Page 42: ...should only be connected once the system has been fully tested Connection is made by 2 leads with spade terminals observe the correct polarity red to positive black to negative Care must be taken to ensure that the terminals of the battery are not shorted together by metal objects as this may constitute a Fire Hazard The Control Cabinet is IP55 rated to exclude dust and is vented to avoid the buil...

Page 43: ...bellissimo 2 72 Way Video Entry System PD 098 Issue 4B Installation and Operating Manual Page 43 of 44 ...

Page 44: ...l rate numbers Tel 0845 121 4008 Sales and Technical Support FAX 0845 121 4009 E mail sales bellsystem co uk technical bellsystem co uk Website www bellsystem co uk Standards This product complies with European directive 89 336 EEC on Electromagnetic Compatibility and Low Voltage Directive 72 23 EEC Emissions Generic BSEN 61000 6 3 Immunity Generic BSEN 61000 6 1 Low Voltage Generic BSEN 60950 BS ...

Reviews: