719S 2 Door Switching Unit
PD-008 Iss 6
Installation & Operation Manual
Page 12 of 20
Technical Specification
Size Boxed
238mm x 189mm x 50mm
Size PCB Only
177mm x 137mm x 18mm
Supply Voltage
11.5V - 15Vrms 50Hz AC or
11.5V - 15V DC
Current Consumption
590mA maximum AC or
290mA maximum DC
Fail-secure Lock output
Same voltage as AC/DC supply, AC if both present.
500mA maximum.
Fail-safe Lock output
Same voltage as the DC supply
500mA maximum
Lock release duration
3, 5, 10 or 20 seconds (typical)
Active time
30, 60, 90 or 120 seconds (typical)
Engage lamp output
Same voltage as AC/DC supply, AC if both present.
100mA maximum.
Exit input
Normally open contact (must be voltage free)
Door Switch Input
Connect passed through to the phones. For DC
phones only. Switch/Contact rating must be 1.0A
@12V minimum for 60 phones. See diagram 7
No. of Doors
2 per unit, maximum of 16 doors per system
Operating Temperature
0
"
C to 50
"
C