background image

 

 

 

 

17

 

 

Configuration 

PPP Configuration 

PPP connection is useful if it is not possible to make a 
direct network connection to the ePowerSwitch

.  Again the 

external modem is needed to connect to the front serial port of 
the NIC Web card of the ePowerSwitch.  

 

Fill in the blank as above in your web and save. 

Summary of Contents for ePowerSwitch F1D001

Page 1: ...User Manual ePowerSwitch By BELKIN 34000179 19 Sep 02 Copyright 2000...

Page 2: ...tion Conventions Used In This Guide This guide uses these conventions Bold italic print as shown in this example indicates field names menu items or values in the ePowerSwitch software agent Bold prin...

Page 3: ...gateway and subnet 7 2 Setup via serial port 8 Serial or Telnet Configuration 11 Use terminal to set IP gateway and subnet 11 3 Setup via USB port 13 4 Telnet Options 15 5 Setup via Ethernet Cascaded...

Page 4: ...ii ii Telephone access interface 27 Appendix 30 Reference 30 Communities 30 IP Addresses 30 Subnetting and Subnet Masks 31 Gateways 33 Glossary 34 Troubleshooting 36...

Page 5: ...ocked up devices or servers Sequentially apply power to equipment that is plugged into the ePowerSwitch Multiple OS support As long as there is Network Management software present Remote setup support...

Page 6: ...ON OFF status for each of the rear output socket respectively from A to H Green LED indicates the Internet remote control or non Internet front panel control status of the corresponding socket You ma...

Page 7: ...tch there is a delay time for the corresponding outlet of the NT card to off the power for the safe shutdown functionality The default delay time is set up as 3 minutes RJ 11 Jacks iLink Port Daisy ch...

Page 8: ...iskette User Manual NIC Web Card w USB Cable RS232 Cable Phone Card NT Card w PC Communication Cable ePowerSwitch iLink Cable for Daisy Chain UPS iLink Cable The ePowerSwitch System Unit Figure 1 show...

Page 9: ...floppy Users are encouraged to use USB setup Requires English version of Windows 98 either first or second edition Serial Port The serial port on the front is designed for initial setup of the card Nu...

Page 10: ...RS232 port using terminal software e g Windows HyperTerminal 3 Setup via USB port using ePowerSwitch USBSetup software USBSetup software included 4 Setup IP address by using ARP command first time on...

Page 11: ...setup IP address only for the first time and the IP address is temporarily 3 Use a Web browserto enter in and configure all ePowerSwitch network parameters with the IP address you setup by ARP command...

Page 12: ...ia serial port Before setup you need 1 IP address Get a valid IP address from administrator 2 RS232 Cable enclose 3 Dumb terminal software ex HyperTerminal in the win95 98 NT Win2000 4 Default passwor...

Page 13: ...connecting the ePowerSwitch System through the serial port 1 Connect the RS232 port to a dumb terminal PC with RS232 cable 2 Setup terminalsoftware 1 Open terminal software select Property in File ca...

Page 14: ...ow configured to communicate with the ePowerSwitch 4 Approximately three seconds after you turn on AC power the terminaldisplays Check u dram Within 5 seconds press when you see Waiting five seconds t...

Page 15: ...Web Card starts up Approximately three seconds after you turn on the power for ePowerSwitch the NIC card displays Check u dram Press when you see Waiting five seconds to enter console configuration Yo...

Page 16: ...nimum requirement to operate ePowerSwitch Systemis to set the IP address If you want to return to the Main Menu press Esc key For more information on IP addresses and net masks see the Reference secti...

Page 17: ...nd USBSetup file Enclose in the disk 1 Connect the ePowerSwitch to a Windows 98 PC through an USB cable If the PC prompts for a new driver insert the floppy provided Uncheck update Windows 98 check bo...

Page 18: ...14 to see the device because the ePowerSwitch takes about 30 seconds to boot 2 The USB interface power device name must appear in the System Properties dialog box before you run the USB setup softwar...

Page 19: ...evice See the following figure You need to run Device Update Restart before closing 4 Telnet Options You can also Telnet to the IP address of the ePowerSwitch System after it has been installed on you...

Page 20: ...er information locally in order to successfully make a Telnet connection 5 Setup via Ethernet Cascaded Cable Before setup you need 1 IP address Get a valid IP address from administrator 2 Ethernet Cas...

Page 21: ...n is useful if it is not possible to make a direct network connection to the ePowerSwitch Again the external modem is needed to connect to the front serial port of the NIC Web card of the ePowerSwitch...

Page 22: ...e PPP configuration ePowerSwitch will then automatically dial up to the designated ISP and send the e mail to the designated e mail address with the assigned IP address from ISP 3 User may browse and...

Page 23: ...19 User Management Administrators canassign the maximum of4 users to control the outlet...

Page 24: ...20 20 Software Update This is the place you can upgrade the firmware when it is available or bug fix...

Page 25: ...Since 16 ePowerSwitches can be daisy chained together to share one NIC so each unit can be individually named The last item Enable waiting device shutdown is dedicated to Microsoft Windows NT 4 and 2...

Page 26: ...ommunication port on the rear of ePowerSwitch to NT or WIN 2000 server with the PC Communication cable Connect the corresponding outlet on the rear of ePowerSwitch to the NT or WIN 2000 server with th...

Page 27: ...23 Scheduled shutdown Scheduled shutdown can be accomplished here Be careful with which outlet you are working...

Page 28: ...NMS Network Management Station a If you do not get a response check the card s network connection and IP address 3 Test the adapter with an NMS Perform a get and a set a If the get or set commands fa...

Page 29: ...lt directory of the TFTP server RS232 Serial Port Console Upgrade The following steps guide you in connecting the ePowerSwitch System through the serial port 1 Connect the RS232 port to a dumb termina...

Page 30: ...26 26 the user data are lost...

Page 31: ...e default password is 123456789 4 The ePowerSwitch will send out a 3 short beep to confirm successful login b A long beep to deny access 5 Once logged in remote user can change ID Address 333XXxx is C...

Page 32: ...rSwitch02 outlet H on after 3600 minutes 02803600 means turn ePowerSwitch02 outlet H off after 3600 minutes 02823600 means reset ePowerSwitch02 outlet H after 3600 minutes Use combination of 0111XXXX...

Page 33: ...what and user input 888XXXXXXXXXX the second time to re confirm and ePowerSwitch acknowledge 4 short beeps indicating password change completed 10 Hang up to close access 11 Each command string shoul...

Page 34: ...so that only trap managers that are members of a community can send requests and receive responses from a particular community This prevents unauthorized managers from viewing or changing the configur...

Page 35: ...ID Host ID Number of Hosts A 1 126 first octet last three octets 16 387 064 B 128 191 first two octets last two octets 64 516 C 192 223 first three octets last octet 254 Any value between 0 and 255 is...

Page 36: ...he host ID For the example above if you want all the devices on the subnetworks to receive each other s IP packets set the subnet mask to 255 255 0 0 If you want the devices on a single subnetwork onl...

Page 37: ...s Gateways Gateway also referred to as a router is any computer with two or more network adapters connecting to different physical networks Gateways allow for transmission of IP packets among networks...

Page 38: ...access the network at the same time LAN hardware manufactures use EtherNet protocol their products may not be compatible Gateway A computer that attaches to a number of networks and routes packets bet...

Page 39: ...nt A software module that manages specific MIB sub groups for an Agent They communicate with the Agent using a SMUX multiplexer TCP IP Transmission Control Protocol Internet Protocol A protocol suite...

Page 40: ...a bits and 1 stop bit The cable is a null serial cable PROBLEM The NMS cannot ping the ePowerSwitch System Solution Make sure the network connection to the ePowerSwitch System is good Solution Make su...

Reviews: