background image

 

 

PDU 4/4 Product Manual, Rev. A     November  2020 

 

Page 8 

 

Installation 

The  PDU  is  designed  to  stand  alone  or  to  connect  to  a 

Thinklogical Secure Console Server

®

. Each device port 

of  the  Secure  Console  Server  is  a  compatible  RS-232 
s

erial port designed to connect to the PDU’s 

CONTROL 

IN

  port.  The  PDU  is  installed  by  first  connecting  to  the 

device port using commands in the Console Server, then 
once connected, by using PDU commands.  

Refer to the

 Console Server Manual 

for Console Server 

information

 (available online a

www.thinklogical.com

 

 

Secure 
Console 
Servers

 

SCS320 Secure Console Server

100-240V -, 0.5A, 50/60 Hz

T2A, 250 VAC

CAUTION!

Replace with same type and rating fuse.

1       2       3        4       5        6       7       8

9      10     11     12     13      14     15     16

17     18     19      20     21      22     23     24

25     26     27      28     29      30     31     32

PORTS

NETWORK 

CONSOLE

www.thinklogical.com

 

Use an Ethernet cable to connect the desired device port to the PDU's CONTROL IN port. The connection is made 
with the device port configured as follows: 

Port Setting for your Terminal Device 

If  your  switch  does  not  have  a  dedicated  'Power  Manager'  port,  you  may  configure  a  serial  port  to  the  following 
settings:  

 

Configure an RS-232 serial port as a DTE (Data Terminal Equipment) port. 

 

Configure the port for 9600 baud, 8 data bits, No Parity, 1 Stop Bit. 

Cascading the PDU Chassis 

If  more  than  eight  switched  AC  Power  ports  are  required,  the  PDU  4/4  configuration  can  be  expanded  by  daisy-
chaining up to sixteen (16) PDU 4/4 chassis. The first PDU 4/4 assume

s the “Master” role, with the Master PDU 4/4’s 

CONTROL OUT Port connected to the next chassis CONTROL IN Port by an RJ45 serial cable. 

 

Box IDs 

Units are only assigned 

master

 or 

slave

 status after logging in, so connect cascaded units prior to login. Before login, 

all boxes display a box ID of 0. The first box assumes the Master box ID of 1. The top-left LED of the upper RJ-45 
connector illuminates at login to indicate which is the Master unit. Additio

nal PDU 4/4 boxes are designated a “Slave” 

status  and  are  automatically  designated  with the  next  sequential  box ID (numbered  2  through  16).  All  commands 
issued to the master unit referencing a slave unit will be passed on to the designated box. The program parameters 
for each PDU 4/4 are stored in that unit. The Master unit only passes commands to the slave units.  

Summary of Contents for thinklogical PDU-000001

Page 1: ...Type text Revision A November 2020...

Page 2: ...ticut 06460 U S A Telephone 1 203 647 8700 All trademarks and service marks are property of their respective owners Subject PDU 4 4 AC Power Distribution Unit Product Manual Revision A November 2020 W...

Page 3: ...cading the PDU Chassis 8 Box IDs 8 Program Storage 9 Communicating with The PDU 4 4 9 Programming Access 9 Log In 9 Commands 9 PDU 4 4 Technical Specifications 15 PDU Models Available From Thinklogica...

Page 4: ...NIAPC Evaluation Scheme GREEN and the U S DoD DISA JITC UCR 2013 APL information assurance standards And Thinklogical Velocity products are the first system with both KVM and video matrix switching c...

Page 5: ...ussed Please read this information thoroughly Introduction Product Overview The PDU 4 4 Thinklogical s PDU 4 4 Power Distribution Unit is an AC Power Switch that remotely controls the power to up to e...

Page 6: ...ding the PDU Chassis on page 8 1 The PDU 4 4 Remote AC Power Distribution Unit Mounting the PDU 4 4 You may choose to rack mount your PDU 4 4 or place it on a shelf or desktop feet included The front...

Page 7: ...on Port 7 Port 8 Yes Display status of power on Port 8 Display Modifiable Description System DAISY Position No Location in DAISY Chain Ctrl Rev No Revision of PDU Offset Current Tare Yes Calibrate cur...

Page 8: ...ote The total power draw for each bank of 4 outlet ports must not exceed 15 Amperes The two internal power supplies that are used to power the PDU system are redundant This feature will allow the unit...

Page 9: ...ted Power Manager port you may configure a serial port to the following settings Configure an RS 232 serial port as a DTE Data Terminal Equipment port Configure the port for 9600 baud 8 data bits No P...

Page 10: ...will automatically log out after 5 minutes of idle time 1 Connect your programming terminal to the CONTROL IN port 2 Press Enter on the keyboard to establish communication Your display should show Pa...

Page 11: ...will access the HELP menu which reviews the programming parameters for the PDU 4 4 system Typing help command name will give specific information for each command Exit Quit The Exit Command logs off t...

Page 12: ...orts may be specified as 1 4 1 2 3 4 All may also be used The Define Port Names command allows the user to give each port an alias and allows the grouping of outlets The Port Number is not changed or...

Page 13: ...rts and Boxes may be referred to by all name implying a group or number Ranges of ports may be specified as 1 4 1 2 3 4 All may also be used Any port may be referred to by either Port Numbers or Port...

Page 14: ...boot 1 all If Ports 1 2 3 in Box 2 are defined as SUN2 then reboot 2 SUN2 to Reboot ports 1 2 3 in box 2 Reboot all outputs in all boxes reboot 0 all Note If any of the selected ports are already ON t...

Page 15: ...s Enabled Temperature is 26 degrees C Output Name Status Delay Current mA 1 Port1 OFF 12 0mA 2 Port2 OFF 12 0mA 3 Port3 OFF 12 0mA 4 Port4 OFF 12 0mA 5 Port5 OFF 12 0mA 6 Port6 OFF 12 0mA 7 Port7 OFF...

Page 16: ...Serial Ports Front Panel Display 2 x 24 Liquid Crystal Display Operating Temperature Humidity 0 to 50 C 32 to 122 F 5 to 95 RH non condensing Enclosure Dimensions Approx 12 25in x 17 50in x 1 75in hi...

Page 17: ...y with all required domestic and many international requirements Regulatory Compliance Thinklogical s products are designed and made in the U S A These products have been tested by a certified testing...

Page 18: ...ographical regions and might not apply to your location This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la cl...

Page 19: ...ize proprietary or customized connectors and cabling Product Serial Number Part Number Thinklogical products have a unique serial number which includes a date code printed on an adhesive label that is...

Page 20: ...products Thinklogical and its suppliers disclaim all other warranties Please refer to your product invoice for the Warranty Terms Conditions Defect remedy shall be the repair or replacement of the pro...

Page 21: ...PDU 4 4 Product Manual Rev A November 2020 Page 20 Appendix A PDU 4 4 Quick Start Guide...

Reviews: