Technical Manual
LioN-Link DeviceNet
Subject to change without notice!
Version 1.0 / June 2010
Page 22 of 27
The respective I/O-module parameters are adjusted by the configuration tool. After the parameter setting a
configuration download is necessary.
Doubleclick on a parameter for setting.
Acyclic access is obtained by using the class 101. The instance complies with the respective module position of the I/O-module
beginning with the first module in LioN-Link line 1. The attribute 11 shows the number of available parameters. The attributes
12 and following correspond to the module parameter byte with its respective meaning.
6.6.
Bit assignment / Process data
The process data are divided into consumer (output) data and producer (input) data. The process data are transferred as a block
according to the DeviceNet specification.
6.6.1.
Process data of the BusHead
The BusHead provides 5 byte producer (input) data that always build up the beginning of the producer (input) data block.
BYTE 0:
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0 0 0 0 US1 US2 KS1 KS2
US1: 1 = Voltage monitoring of LioN-Link line 1 reports diagnostics.
0 = Voltage level on LioN-Link line is ok.
US2: 1 = Voltage monitoring of LioN-Link line 2 reports diagnostics.
0 = Voltage level on LioN-Link line is ok.
KS1: 1 = Short-circuit monitoring of LioN-Link line 1 reports diagnostics.
0 = No short circuit on LioN-Link line 1.
KS2: 1 = Short-circuit monitoring of LioN-Link line 2 reports diagnostics.
0 = No short circuit on LioN-Link line 2.