42
5 Technical Data
Version 05 07/2014
Repeater
OZD Genius G12
OZD Genius G12-1300
Ord. code
933 989-021
934 233-021
Safety
VDE regulation
IEC/EN 60950
Electromagnetic compatibility (EMC)
Immunity for industrial environments according
EN 61000-6-2:2001
Electrostatic discharge (ESD)
Satisfies EN 61000-4-2; 4 kV contact discharge, 8 kV air
discharge, HCP/VCP 4 kV
Electromagnetic field
Satisfies EN 61000-4-3; 10 V/m (80 MHz - 1000 MHz)
Fast transients (burst)
Satisfies EN 61000-4-4; 2 kV power line, 1 kV data line
Surge
SatisfiesEN 61000-4-5; 1 kV data line, line-to-line 0.5 kV,
line-to-earth 0.5 kV
Line-conducted disturbances
Satisfies EN 61000-4-6; 10 V (150 kHz - 80 MHz)
Interference emissions
Satisfies EN 55022; Class B
Satisfies FCC CFR47 Part 15; Class B
Climatic ambient conditions
Ambient temperature
0 °C to + 55 °C (IEC 60068-2-1, IEC 60068-2-2)
Storage temperature
– 40 °C to + 80 °C (IEC 60068-2-14)
Relative humidity
< 95 % (non-condensing) (IEC 60068-2-30)
Mechanical ambient conditions
Vibration (during operation)
10 to 58 Hz, 0.075 mm displacement;
58 to 150 Hz, 10 m/s
2
(1 g) acceleration (IEC 60068–2–6)
Vibration (during transport)
5 to 9 Hz, 3.5 mm displacement;
9 to 500 Hz, 10 m/s
2
(1 g) acceleration
Degree of protection
IP 40
Weight
530 g
Dimensions W × H × D
40 × 133 × 90 mm (with connectors)
Housing material
Die-cast zinc / sheet aluminum
The repeater does not contain any silicone.
6 Application Support
Contact address for technical support
Hirschmann Automation and Control GmbH
Stuttgarter Strasse 45 - 51
72654 Neckartenzlingen
Germany
Tel.:
+49 (0)1805 14-1538
Fax:
+49 (0)7127 14-1551
E-Mail: [email protected]
Internet: http://www.hirschmann.com