Installation OBR40
Release 01 04/2013
25
EMC
EMC interference emission
Standard applications
Radiated emission
EN 55022
Class B
Conducted emission
EN 55022
Class B
EMC interference immunity
Standard applications
Electrostatic discharge
EN 61000-4-2
Contact discharge
± 4 kV
Air discharge
± 8 kV
Electromagnetic field
EN 61000-4-3
80 MHz ... 1000 MHz
10 V/m
1.4 GHz ... 2 GHz
3 V/m
2 GHz ... 2.7 GHz
1 V/m
Fast transients (burst)
EN 61000-4-4
DC supply connection
± 2 kV
Data line
± 1 kV
Voltage surges - DC supply connection
EN 61000-4-5
line/ground
± 0.5 kV
line/line
± 0.5 kV
Conducted disturbances
EN 61000-4-6
150 kHz ... 80 MHz
10 V