Media modules: Power consumption, Power output,
operating temperature surrounding air, order numbers
Module
Power
consump-
tion
Power output
Operating
temperature
(ambient air
temperature)
Order
number
MM2 media modules:
MM2-4TX1
0,8 W
2,8 Btu (IT)/h
0 °C ... +60 °C
943 722-101
MM2-4TX1-EEC
0,8 W
2,8 Btu (IT)/h
−
40 °C ... +70 °C
943 722-151
MM2-4FXM3
6,8 W
23,2 Btu (IT)/h
0 °C ... +60 °C
943 721-101
MM2-2FXM3/2TX1
3,8 W
13,0 Btu (IT)/h
0 °C ... +60 °C
943 720-101
MM2-2FXM2
3,8 W
13,0 Btu (IT)/h
0 °C ... +60 °C
943 718-101
MM2-2FXS2
3,8 W
13,0 Btu (IT)/h
0 °C ... +60 °C
943 719-101
MM3 media modules:
MM3-2AUI
3,4 W
11,6 Btu (IT)/h
0 °C … +60 °C
943 840-101
MM3-4FLM4
5,0 W
17,1 Btu (IT)/h
0 °C ... +60 °C
943 760-101
MM3-2FLM4 / 2TX1-RT
5,0 W
17,1 Btu (IT)/h
0 °C ... +60 °C
943 117-004
MM3-4TX5
0,8 W
2,8 Btu (IT)/h
0 °C ... +60 °C
943 841-101
MM3-4TX1-RT
0,8 W
2,8 Btu (IT)/h
0 °C ... +60 °C
943 117-001
MM3-1FXM2/3TX1
2,3 W
7,9 Btu (IT)/h
0 °C ... +60 °C
943 839-101
MM3-2FXM2/2TX1
3,8 W
13,0 Btu (IT)/h
0 °C ... +60 °C
943 761-101
MM3-2FXM2/2TX1-EEC
3,8 W
13,0 Btu (IT)/h
−
40 °C ... +70 °C
943 761-151
MM3-2FXM2 / 2TX1-RT
3,8 W
13,0 Btu (IT)/h
0 °C ... +60 °C
943 117-002
MM3-2FXM4/2TX1
3,8 W
13,0 Btu (IT)/h
0 °C ... +60 °C
943 837-101
MM3-4FXM2
6,8 W
23,2 Btu (IT)/h
0 °C ... +60 °C
943 764-101
MM3-4FXM4
6,8 W
23,2 Btu (IT)/h
0 °C ... +60 °C
943 835-101
MM3-1FXS2/3TX1
2,3 W
7,9 Btu (IT)/h
0 °C ... +60 °C
943 838-101
MM3-1FXS2 / 3TX1 EEC
2,3 W
7,9 Btu (IT)/h
−
40 °C ... +70 °C
943 838-151
MM3-2FXS2/2TX1
3,8 W
13,0 Btu (IT)/h
0 °C ... +60 °C
943 762-101
MM3-2FXS2/2TX1 EEC
3,8 W
13,0 Btu (IT)/h
−
40 °C ... +70 °C
943 762-151
MM3-4FXS2
6,8 W
23,2 Btu (IT)/h
0 °C ... +60 °C
943 836-101
MM3-1FXL2/3TX1
3,4 W
11,6 Btu (IT)/h
0 °C ... +60 °C
943 763-101
MM4 media modules:
MM4-4TX/SFP
9,0 W
30,8 Btu (IT)/h
0 °C ... +60 °C
943 010-001
MM4-2TX/SFP
5,8 W
19,8 Btu (IT)/h
0 °C ... +60 °C
943 622-001
Open variant media modules:
MM20-... 4 TX-/0 FX-Ports 0,8 W
2,8 Btu (IT)/h
See table 17.
See table 17.
MM20-... 3 TX-/1 FX-Ports 2,3 W
7,9 Btu (IT)/h
- “ -
- “ -
MM20-... 2 TX-/2 FX-Ports 3,8 W
13,0 Btu (IT)/h - “ -
- “ -
MM20-... 0 TX-/2 FX-Ports 3,8 W
13,0 Btu (IT)/h - “ -
- “ -
MM20-... 1 TX-/3 FX-Ports 5,3 W
18,1 Btu (IT)/h - “ -
- “ -
MM20-... 0 TX-/4 FX-Ports 6,8 W
23,2 Btu (IT)/h - “ -
- “ -
MM20-A8A89999...
3,4 W
11,6 Btu (IT)/h - “ -
- “ -
MM20-F4F4F4F4...
5,0 W
17,1 Btu (IT)/h - “ -
- “ -
MM20-Z6Z6Z6Z6...
8,0 W
27,3 Btu (IT)/h
- “ -
- “ -
MM20-P9P9P9P9SAHH
8,0 W
27,3 Btu (IT)/h
0 °C ... +60 °C
- “ -
Table 16: Media modules: power, temperature, order numbers