48
MACH 4000
Release 11/08
3
Technical data
General technical data
Dimensions
MACH 4002-...
M4-POWER
W x H x D: 480 mm x 88 mm x 435 mm
W x H x D: 480 mm x 88 mm x 435 mm
Assembly
MACH 4002-...
M4-POWER
19" switch cabinet
19" switch cabinet
Weight
MACH 4002-...
7.5 kg
Power supply
MACH 4002-...
M4-S-xx power unit or power unit chassis
M4-POWER with M4-P-xx power unit,
please order separately
Operating voltage
M4-S-AC/DC 300W
M4-S-24VDC 300W
M4-S-48VDC 300W
100-240 VAC +/- 10%
24 VDC (19.2 V - 32 V)
1
48 VDC (38.4 V - 60 V)
1
1.
NEC Class 2 power source safety extra-low voltage (SELV/PELV)
M4-P-AC/DC 300W
M4-P-24VDC 300W
M4-P-48VDC 300W
100-240 VAC +/- 10%
24 VDC (19.2 V - 32 V)
1
48 VDC (38.4 V - 60 V)
1
Buffer time
M4-P-AC/DC 300W
M4-...-24VDC 300W
M4-...-48VDC 300W
min. 1/2 mains period
min. 10 ms at 20.4 VDC
min. 10 ms at 40.8 VDC
Current consump-
tion
M4-S-AC/DC 300W
M4-S-24VDC 300W
M4-S-48VDC 300W
max. 1.7 A (240 VAC), max. 4.0 A (100 VAC)
max. 16.0 A (24 VDC), max. 20 A (19.2 - 32 VDC)
max. 8.0 A (48 VDC), max. 10 A (38.4 - 60 VDC)
M4-P-AC/DC 300W
M4-P-24VDC 300W
M4-P-48VDC 300W
max. 1.7 A (240 VAC), max. 4.0 A (100 VAC)
max. 16.0 A (24 VDC), max. 20 A (19.2 - 32 VDC)
max. 8.0 A (48 VDC), max. 10 A (38.4 - 60 VDC)
Activation current
M4-S-AC/DC 300W
M4-P-AC/DC 300W
typ. <40 A at 265 VAC and cold start
typ. <40 A at 265 VAC and cold start
Overload current
protection at input
Non-replaceable fuse
Potential difference
between incoming
voltage and hous-
ing
M4-...-...VDC 300W
Potential difference from incoming voltage
+24 VDC/ +48VDC: 60 VDC
Potential difference from incoming voltage 0V:
60 VDC
2
Environment
Storage temperature
Humidity
Air pressure
Ambient air: -25 °C to +70 °C
10% to 95% (non-condensing)
Up to 2000 m (795 hPa), higher altitudes on re-
quest
Operating temper-
ature
MACH 4002-...
M4-S-xx, M4-P-xx
M-SFP-xx/xx
M-XFP-xx/xx
M-FAST SFP-xx/xx
M4-8TP-RJ45
M4-8TP-RJ45 PoE
M4-FAST 8-SFP
M4-GIGA 8-SFP
With M4-AIR plug-in fan unit:
Ambient air: 0 °C°C to +60 °C
With M4-AIR-L plug-in fan unit:
Ambient air: 0 °C to +40 °C
Pollution degree
2
Protection classes Laser protection
Protection class
Class 1 according to EN 60825-1 (2001)
IP 20
Summary of Contents for HIRSCHMANN MACH 4000 Series
Page 56: ......