32
Installing MAMMUTHUS SWITCH
Published on 01 01/2020
2.5
Operate equipment
Follow the steps below:
Use screws to secure the connector to the equipment.
You can refer to the specified tightening torque in the
“General technical
data” on page 38
.
Enable the supply voltage.
2.6
Connect data cable
In environments with high electrical interference, note the following general
recommendations for data cable connections:
Minimize the length of the data cable.
Use fiber-optic data cables for data transmission between buildings.
Try to separate the power cable from the data cable sufficiently if there are
copper cables used. It is best to install it in a separate channel.
Make sure the power cable and data cable are not laid out in parallel over a
long distance, preferably in separate cable channels. To reduce inductive
coupling, make sure the power and data cables intersect at 90°.
Use SF/UTP cable conformed to ISO/IEC 11801:2002.
Connect the data cable according to your requirements.
Note: Only shielded twisted pair cables are allowed in DNV GL EMC Class B
area.
For more information:
Refer to “Equipment name and product code” on page 16.
2.7
Fill in the Device Label
MAC address on the front helps you identify the equipment.
Summary of Contents for HIRSCHMANN IT MAMMUTHUS MTM2900-FAN
Page 19: ...Installing MAMMUTHUS SWITCH Published on 01 01 2020 19 1 3 2 Power module ...
Page 20: ...20 Installing MAMMUTHUS SWITCH Published on 01 01 2020 1 3 3 Fan module ...
Page 41: ...Installing MAMMUTHUS SWITCH Published on 01 01 2020 41 7 2 Size diagram Basic device ...
Page 42: ...42 Installing MAMMUTHUS SWITCH Published on 01 01 2020 Power module ...
Page 43: ...Installing MAMMUTHUS SWITCH Published on 01 01 2020 43 Fan module ...
Page 52: ...52 Installing MAMMUTHUS SWITCH Published on 01 01 2020 ...