background image

Installation BAT867-R

Release 10 09/2021

Technical support

https://hirschmann-support.belden.com

User Manual

Installation
Industrial Access-Point / Client / Access-Bridge
BAT867-R

Summary of Contents for Hirschmann BAT867-R

Page 1: ...Installation BAT867 R Release 10 09 2021 Technical support https hirschmann support belden com User Manual Installation Industrial Access Point Client Access Bridge BAT867 R...

Page 2: ...wn use The performance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH accor...

Page 3: ...1 5 1 Pin assignments 26 1 6 Connections for antennas 27 1 7 Display elements 27 1 7 1 Device state 27 1 8 Reset button 28 2 Installation 29 2 1 Checking the package contents 29 2 2 Installing and gr...

Page 4: ...device 43 10 Technical data 44 10 1 General technical data 44 10 2 Dimension drawings 45 10 3 Radio technology 46 10 4 Roaming 46 10 5 Receiving sensitivity transmit power and data rate 47 10 5 1 IEE...

Page 5: ...njury or death If this symbol is displayed in addition to a safety instruction of the type Danger or Warning it means that there is a danger of electric shock and failure to observe the instructions w...

Page 6: ...6 Installation BAT867 R Release 10 09 2021 NOTICE NOTE provides information about procedures that do not involve the risk of injury...

Page 7: ...ion Certified usage Use the product only for the application cases described in the Hirschmann product information including this manual Operate the product only according to the technical specificati...

Page 8: ...t damage to device connections connectors and cables follow the instructions for proper installation in accordance with DIN VDE 0100 520 2013 06 sections 522 6 522 7 and 522 13 Device casing Only tech...

Page 9: ...LAN device with regard to the general operating permission and the maximum emission levels Install and operate this equipment with a minimum distance of 50 cm 19 7 in between the antenna and your body...

Page 10: ...y without restrictions The electrical wires are voltage free The cables used are permitted for the temperature range of the application case The voltage connected complies with the requirements for a...

Page 11: ...of 0 5 mm to 0 75 mm AWG20 up to AWG18 The cross section of the ground conductor is the same size as or bigger than the cross section of the power supply cables The following requirements apply alter...

Page 12: ...igate the effects of lightning strikes CE marking The labeled devices comply with the regulations contained in the following European directive s 2011 65 EU and 2015 863 EU RoHS Directive of the Europ...

Page 13: ...e instructions must be strictly adhered to in order to observe the EMC threshold values Notes for countries with the following country codes The RED compliance requires compliant operation of the devi...

Page 14: ...dition The usage of this band is restricted to commercial public telecommunication services Registration at the Federal Network Agency is required Name and website of the competent authority Bundesnet...

Page 15: ...d Electronical Equipment Regulations S I 2017 No 1206 Radio Equipment Regulations The UKCA conformity declaration will be available to the relevant authorities at the following address Belden UK Ltd 1...

Page 16: ...n of the country setting To obtain the Radio Equipment Regulations compliance perform the work steps described in chapter Obtaining compliance for operation in the European Union and in the United Kin...

Page 17: ...lation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications How...

Page 18: ...s transmitter is restricted to indoor use only within the 5 15 to 5 25 GHz band to reduce potential for harmful interference to co channel mobile satellite systems This Class B digital apparatus compl...

Page 19: ...If other antennas are used the approval expires The responsibility lies with the operator of the system The required antenna impedance is 50 Recycling note After usage this device must be disposed of...

Page 20: ...ption safety instructions a description of the display and the other information that you need to install the device Documentation mentioned in the User Manual Installation that is not supplied with y...

Page 21: ...Installation BAT867 R Release 10 09 2021 21 Key The symbols used in this manual have the following meanings Listing Work step Subheading...

Page 22: ...ltiple Input Multiple Output and Multipath The bandwidth is increased by using the multipath transmission by means of reflections 2 antennas for sending and receiving help ensure stable network covera...

Page 23: ...ntry approvals Example Singapore XX Example SG You can determine the current country approvals using the configurator https catalog belden com 11 Slot 1 W WLAN module 12 Slot 2 9 Not assembled 13 Slot...

Page 24: ...3 Device view 1 Functional earth screw 2 2 pin terminal block for the supply voltage 3 LED display elements 4 Reset button 5 Antenna connection 1 6 Antenna connection 2 7 RJ45 socket for 10 100 1000...

Page 25: ...100 1000 Mbit s twisted pair port allows you to connect network components according to the IEEE 802 3 10BASE T 100BASE TX 1000BASE T standard This port supports Autonegotiation Autopolarity Autocross...

Page 26: ...1 5 1 Pin assignments RJ45 Pin 10 100 Mbit s 1000 Mbit s MDI mode 1 TX BI_DA 2 TX BI_DA 3 RX BI_DB 4 BI_DC 5 BI_DC 6 RX BI_DB 7 BI_DD 8 BI_DD MDI X mode 1 RX BI_DB 2 RX BI_DB 3 TX BI_DA 4 BI_DD 5 BI_D...

Page 27: ...ice performs a self test During this process various LEDs light up 1 7 1 Device state These LEDs provide information about conditions which affect the operation of the whole device P Color Activity Me...

Page 28: ...or download on the Internet https www doc hirschmann com green inverse flashing Number of flashes corresponds to number of connected WLAN stations and P2P radio lines green flashing DFS scanning or an...

Page 29: ...g the device Connecting data cables Making basic settings Configuring the transmit power 2 1 Checking the package contents Check whether the package includes all items named in the section Scope of de...

Page 30: ...r and press the lower part of the device against the DIN rail Snap in the device by releasing the rail lock slide 2 2 2 Grounding the device Prerequisite Use a wire diameter for the functional earth c...

Page 31: ...erminating resistor SMA to ANT2 for RSMA ANT connectors You will find information on setting the transmit power in chapter Configuring the transmit power on page 39 2 4 Connecting the terminal blocks...

Page 32: ...vice Type of the voltages that can be connected Specification of the supply voltage Pin assignment on the device DC voltage Rated voltage 24 V DC Voltage range incl maximum tolerances 18 V DC 32 V DC...

Page 33: ...Use optical data cables for the data transmission between the buildings When using copper cables provide a sufficient separation between the power supply cables and the data cables Ideally install th...

Page 34: ...t time The device provides the following options for configuring IP addresses Entry via the HiDiscovery protocol in the applications HiDiscovery or Industrial HiVision Configuration via BOOTP You will...

Page 35: ...rst time you log on to the device Log on to the device with the default password private The device prompts you to type in a new password Note When you log on with LANconfig the device prompts you to...

Page 36: ...interface WEBconfig or the LANconfig software You can download the LANconfig software from the Hirschmann product pages www hirschmann com Perform the following work steps Command Line Interface CLI T...

Page 37: ...specific channels in comparison to the Europe country setting The device ignores specific country settings and uses the country setting Europe until the RED compliance or the Radio Equipment Regulati...

Page 38: ...urope until the RED compliance or the Radio Equipment Regulations compliance has been obtained To confirm your choice click the OK button In the LANconfig device overview highlight the row containing...

Page 39: ...the Configuration Wireless LAN General dialog In the General tab specify in the General frame the country in which you install the device and click the Send button Note For devices that are operated i...

Page 40: ...on BAT867 R Release 10 09 2021 Subtract from the antenna gain the attenuation by cables and by surge protection devices Enter the calculated value in the Antenna gain field To save the value click the...

Page 41: ...let a WLAN expert make the adjustments Use the graphical user interface WEBconfig or the LANconfig software You can download the LANconfig software from the Hirschmann product pages www hirschmann co...

Page 42: ...king on improving and developing their software Check regularly whether there is an updated version of the software that provides you with additional benefits You find information and software downloa...

Page 43: ...es Disable the supply voltage Remove the terminal connector from the device Remove the antennas Disconnect the grounding Insert a screwdriver horizontally below the housing into the locking gate Pull...

Page 44: ...A2s Climatic conditions during operation Minimum clearance around the device Top and bottom sides of device 5 cm 2 in Left and right device side 2 cm 0 79 in Ambient air temperaturea a Temperature of...

Page 45: ...Installation BAT867 R Release 10 09 2021 45 10 2 Dimension drawings 147 5 5 81 142 4 5 61 134 8 5 31 122 5 4 82 117 3 4 62 118 2 4 65 113 1 4 45 mm inch 49 4 1 94 31 1 22...

Page 46: ...and data rate Encryption IEEE 802 11i WPA2 with passphrase or IEEE 802 1x and hardware accelerated AES Closed Network WEP 64 WEP 128 WEP 152 User authentication 802 1x EAP LEPS WPA1 TKIP For more inf...

Page 47: ...11b 10 5 2 IEEE 802 11g IEEE 802 11b Frequency range 2 412 GHz to 2 472 GHz Bandwidth 20 MHz Data rate Transmit power Receiving sensitivity 1 Mbit s 23 dBm 95 dBm 2 Mbit s 23 dBm 94 dBm 5 5 Mbit s 23...

Page 48: ...to 5 825 GHz bandwidth 20 MHz IEEE 802 11n Frequency range 2 412 GHz to 2 472 GHz Bandwidth 20 MHz Coding Transmit power Receiving sensitivity MCS 0 8 24 dBm 93 dBm MCS 1 9 24 dBm 91 dBm MCS 2 10 24...

Page 49: ...77 dBm MCS 6 14 19 dBm 74 dBm MCS 7 15 17 dBm 73 dBm Table 10 IEEE 802 11n frequency range 5 180 GHz to 5 825 GHz bandwidth 20 MHz IEEE 802 11n Frequency range 5 180 GHz to 5 825 GHz Bandwidth 40 MHz...

Page 50: ...7 dBm 73 dBm MCS 8 16 dBm 71 dBm Table 12 IEEE 802 11ac frequency range 5 180 GHz to 5 825 GHz bandwidth 20 MHz IEEE 802 11ac Frequency range 5 180 GHz to 5 825 GHz Bandwidth 40 MHz Coding Transmit po...

Page 51: ...dBm 84 dBm MCS 3 20 dBm 81 dBm MCS 4 20 dBm 77 dBm MCS 5 19 dBm 74 dBm MCS 6 18 dBm 73 dBm MCS 7 17 dBm 70 dBm MCS 8 16 dBm 67 dBm MCS 9 16 dBm 65 dBm Table 14 IEEE 802 11ac frequency range 5 180 GHz...

Page 52: ...round Data line unshielded 1 kV EN 61000 4 6 Conducted disturbances 150 kHz 80 MHz 10 V EMC interference emission EN 55032 Class B Immunity IEC 60068 2 6 test Fc Vibration 5 Hz 8 4 Hz with 3 5 mm 0 14...

Page 53: ...vice 1 Safety and general information sheet 1 Sheet with the conformity declarations for the European Union and the United Kingdom UK 1 premounted 2 pin terminal block for the supply voltage Amount Ar...

Page 54: ...to IP20 For reliable receive power and transmission power you require antennas that pertain to your application case The Antenna Guide document provides an overview of the antennas that can be used as...

Page 55: ...onments EN 61131 2 Programmable controllers Part 2 Equipment requirements and tests EN 300 328 Electromagnetic compatibility and radio spectrum matters ERM bandwidth transfer systems data transmission...

Page 56: ...titors on three counts with its complete range of innovative services Consulting incorporates comprehensive technical advice from system evaluation through network planning to project planning Trainin...

Page 57: ...Installation BAT867 R Release 10 09 2021 57...

Page 58: ......

Reviews: