![Belden grass valley IQSDA41 Series User Manual Download Page 24](http://html.mh-extra.com/html/belden/grass-valley-iqsda41-series/grass-valley-iqsda41-series_user-manual_2725436024.webp)
24
Technical Specifications
Optical
12 Gbit/s UHD-1
3 Gbit/s HD-SDI
1.485 Gbit/s HD-SDI
270 Mbit/s SD-SDI
Connector/Format
LC single mode
Conforms to
SMPTE 297-2006
SMPTE 424M (HD level A/B)
SMPTE 292M (HD)
SMPTE 259M-C (SD)
* Dependant on SFP fitted
Controls
Indicators:
Power
OK (Green)
CPU
OK (Green flashing)
Input 1
OK (Green), Bypass (Orange), Loss (Red)
Input 2
OK (Green), Bypass (Orange), Loss (Red)
Input 3 (IQSDA42 only)
OK (Green), Bypass (Orange), Loss (Red)
Input 4 (IQSDA42 only)
OK (Green), Bypass (Orange), Loss (Red)
SFP A
OK (Green), Bypass (Orange), Loss (Red)
SFP B
OK (Green), Bypass (Orange), Loss (Red)
Other Controls
User Memories
Name, save, and recall 16 user memories
Memory Naming
User configurable naming of memories 1–16
Information Window
Unit Status, SFP Status
Logging
Input 1-4 Type
Input 1-4 Data Rate
Input 1-4 Present
Input 1-4 Error
Input 1-4 Loss
Optical Logging
Tx Laser Bias High Warning
Tx Power Low Warning
Tx Power High Warning
Laser Wavelength
Input 1 (2) Rx Power High Warning
Input 1 (2) Rx Power Low Warning
Input 1 (2) Rx Power Measurement
RollTrack Index
Up to 16 RollTrack destinations
RollTrack Controls
On/Off, Index, Source, Address, Command, Status, Sending
Roll Track Sources
Unused, Input Present (1-4, Fiber 1 & 2), Input Loss (1-4, Fiber 1 & 2),
Output Rate/Std (1 -4), Out 1 Selects (In 1-4 & Rx 1 & Rx 2), Fiber Rx
Power OK (1 & 2), Fiber Rx Power Fail (1 & 2), Fiber Tx Bias OK (1 & 2),
Fiber Tx Bias High (1 & 2), Fiber Tx Bias Low (1 & 2)
Summary of Contents for grass valley IQSDA41 Series
Page 14: ...xiv Notices ...
Page 16: ...xvi Table of Contents ...
Page 26: ...26 Technical Specifications ...
Page 28: ...28 Connections SDI SFP ...
Page 30: ...30 Rear Panel LEDs ...
Page 50: ...50 Operation Using the RollCall Control Panel Memory 1 16 ...