Belden grass valley IQSDA41 Series User Manual Download Page 1

User Manual

Issue 2 Revision 1

2019-04-01

IQSDA41/42

SINGLE/DUAL/MULTI-CHANNEL RE-CLOCKING DISTRIBUTION 

AMPLIFIERS WITH ROLLCALL

Summary of Contents for grass valley IQSDA41 Series

Page 1: ...User Manual Issue 2 Revision 1 2019 04 01 IQSDA41 42 SINGLE DUAL MULTI CHANNEL RE CLOCKING DISTRIBUTION AMPLIFIERS WITH ROLLCALL ...

Page 2: ...y hereby grants permission and license to owners of IQSDA41 42 to use their product manuals for their own internal business use Manuals for GrassValley products may not be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying and recording for any purpose unless specifically authorized in writing by Grass Valley A Grass Valley manual may have been re...

Page 3: ... be connected to earth ground as a supplement to an internal grounding terminal Indicates that static sensitive components are present which may be damaged by electrostatic discharge Use anti static procedures equipment and surfaces during servicing Indicates that the equipment has more than one power supply cord and that all power supply cords must be disconnected before servicing to avoid electr...

Page 4: ...onnecting power Prior to servicing remove jewelry such as rings watches and other metallic objects To avoid fire hazard use only the fuse type and rating specified in the service instructions for this product or on the equipment To avoid explosion do not operate this equipment in an explosive atmosphere Use proper lift points Do not use door latches to lift or move equipment Avoid mechanical hazar...

Page 5: ...nect the grounding clip to an unpainted surface of the chassis frame to safely ground unwanted ESD voltages If no wrist strap is available ground yourself by touching the unpainted metal part of the chassis For safety periodically check the resistance value of the antistatic strap which should be between 1 and 10 megohms When temporarily storing a card make sure it is placed in an ESD bag Cards in...

Page 6: ...e borne de mise à la terre externe qui peut être connectée en tant que borne de mise à la terre supplémentaire Signale la présence de composants sensibles à l électricité statique et qui sont susceptibles d être endommagés par une décharge électrostatique Utilisez des procédures des équipements et des surfaces antistatiques durant les interventions d entretien Le symbole ci contre signifie que l a...

Page 7: ...isez uniquement un chiffon humide Des tensions dangereuses peuvent exister en plusieurs points dans cet équipement Pour éviter toute blessure ne touchez pas aux connexions ou aux composants exposés lorsque l appareil est sous tension Avant de procéder à toute opération d entretien ou de dépannage enlevez tous vos bijoux notamment vos bagues votre montre et autres objets métalliques Pour éviter tou...

Page 8: ...eut se produire lorsque des composants électroniques ne sont pas manipulés de manière adéquate ce qui peut entraîner des défaillances intermittentes ou endommager irrémédiablement un circuit électrique Au moment de remplacer une carte dans un châssis prenez toujours les mesures de protection antistatique appropriées Assurez vous que le châssis est relié électriquement à la terre par le cordon d al...

Page 9: ...is ingérer le liquide La toxicité est extrêmement faible mais la prudence demeure de mise en tout temps Environmental Information European CE WEEE directive This symbol on the product s means that at the end of life disposal it should not be mixed with general waste Visit www grassvalley com for recycling information Grass Valley believes this environmental information to be correct but cannot gua...

Page 10: ...older using a blunt instrument for leverage such as a screwdriver if necessary In some cases the battery will need to be desoldered from the PCB 4 Dispose of the battery and equipment according to your local environmental laws and guidelines WARNING Be careful not to short circuit the battery by adhering to the appropriate safe handling practices Do not dispose of batteries in a fire as they may e...

Page 11: ...rect exposure to the laser beam Even though the power of these lasers is low the beam should be treated with caution and common sense because it is intense and concentrated Laser radiation can cause irreversible and permanent damage of eyesight Please read the following guidelines carefully Make sure that a fiber is connected to the board s fiber outputs before power is applied If a fiber cable e ...

Page 12: ...l to use cables and connectors with good EMC characteristics All signal connections including remote control connections shall be made with screened cables terminated in connectors having a metal shell The cable screen shall have a large area contact with the metal shell SIGNAL DATA PORTS For unconnected signal data ports on the unit fit shielding covers For example fit EMI blanking covers to SFP ...

Page 13: ...ade with high quality double screened coaxial cables such as Belden 8281 or BBC type PSF1 2M and Belden 1694A for 3Gbps D TYPE CONNECTORS D type connectors shall have metal shells making good RF contact with the cable screen Connectors having indents which improve the contact between the plug and socket shells are recommended ...

Page 14: ...xiv Notices ...

Page 15: ... Block Diagram 19 Feature Summary 20 Order Codes 20 Enclosures 22 2 Technical Specifications 23 3 Connections 27 SDI Input Output 27 SDI SFP 27 4 Rear Panel LEDs 29 5 Operation Using the RollCall Control Panel 31 Navigating Pages in the RollCall Template 31 Information Window 32 Setup Setup SFP 33 Input Output Input Output SFP 35 SFP 37 Logging Misc 39 Logging Input 41 Logging Output 1 n SFP 43 Ro...

Page 16: ...xvi Table of Contents ...

Page 17: ...ion of wide band signals make it ideal for all distribution applications Variants are available with 10 x BNC I O IQSDA4100 1B4 or 8 x BNC I O 2 x SFP I O IQSDA4101 1B4 See Order Codes on page 20 for more information Block Diagram Block Diagram IQSDA41 Feature Summary The IQSDA41 provides the following features Intelligent UHD 1 12 Gbit s HD 3 Gbit s or 1 5 Gbit s and SD SDI re clocking distributi...

Page 18: ...he IQSDA42 is a configurable single dual or quad channel SDI distribution amplifier for UHD 1 12 Gbit s HD 3 Gbit s 1 5 Gbit s or SD 270 Mbit s signals providing up to 19 equalized and re clocked outputs of the input in a single width package Its 60m 12G 80m 3G 180m HD input equalization performance coupled with excellent packing density make it ideal for signal dense distribution applications Var...

Page 19: ... features Intelligent UHD 1 12 Gbit s HD 3 Gbit s or 1 5 Gbit s and SD SDI re clocking distribution amplifier Configurable as 1 input to 9 outputs or 2 inputs with 4 outputs per input Equalizes up to 60m at 12 Gbit s 80m at 3 Gbit s 180m at 1 5 Gbit s and more than 350m at 270 Mbit s when using Belden 1694A cable ...

Page 20: ...tputs per input 2 SFP optical inputs or 2 SFP optical outputs IQSDA4101 1B4 12G 3G HD SD SDI Re clocking Distribution Amplifier 1 input with 9 outputs or 2 inputs with 4 outputs per input IQSDA4200 1B4 Multi channel 12G 3G HD SD SDI Re clocking Distribution Amplifier 1 input with 15 outputs 2 inputs with 7 outputs per input or 4 inputs with 3 outputs per input 1 SFP optical input and 1 SFP optical...

Page 21: ...FC1 R2 Fiber SFP module for Cage 1 2 x 3G Fiber Rx FGAN FC1 R2 HS Fiber SFP module for Cage 1 2 x 3G Fiber Rx 9 to 28dBm FGAN FC1 13R2 12G Fiber SFP module for Cage 1 2 x 12G Fiber Rx FGAN FC1 13TR Fiber SFP module for Cage 1 3G Fiber Tx Rx FGAN FC1 12TR 12G Fiber SFP module for Cage 1 12G Fiber Tx Rx FGAN FC1 HDBT2 HD BNC SFP module for Cage 1 2 x 3G Tx HD BNC FGAN FC1 HDBR2 HD BNC SFP module for...

Page 22: ...22 Introduction Order Codes IQH4B S P Note The IQH3B and IQH4B enclosures provide two internal analog reference inputs These inputs are applicable to modules with B order codes only ...

Page 23: ...ixed HD and SD inputs it is recommended that cable lengths do not exceed the HD specification of 180 m Fiber Signal Input Inputs 2 Optical 12 Gbit s UHD 1 3 Gbit s HD SDI 1 485 Gbit s HD SDI 270 Mbit s SD SDI Connector Format LC single mode Conforms to SMPTE 2082 SMPTE 297 2006 SMPTE 424M HD level A B SMPTE 292M HD SMPTE 259M C SD Signal Outputs Outputs Up to 19 group selectable Connector Format H...

Page 24: ...ies Name save and recall 16 user memories Memory Naming User configurable naming of memories 1 16 Information Window Unit Status SFP Status Logging Input 1 4 Type Input 1 4 Data Rate Input 1 4 Present Input 1 4 Error Input 1 4 Loss Optical Logging Tx Laser Bias High Warning Tx Power Low Warning Tx Power High Warning Laser Wavelength Input 1 2 Rx Power High Warning Input 1 2 Rx Power Low Warning In...

Page 25: ...259M C DVB ASI Connector Format HD BNC 75 Ohm LC singlemode SFP Return Loss 15 dB 270 Mbit s 1 5 Gbit s 10 dB 3 Gbit s Output Jitter SD SDI 0 2 UI 10 Hz 0 2 UI 1 kHz 3G HD SDI 1 0 UI 10 Hz 0 2 UI 100 kHz Optical 1310 nm Tx Wavelength 1310 nm Spectral Width FWHM 1 5 nm typical Output Power 0 to 5 dBm 2 dBm typical Rise and Fall Time 45 ps 12 Gbit s 135 ps 3 Gbit s 270 ps 1 5 Gbit s 1 5 ns 270 Mbit ...

Page 26: ...26 Technical Specifications ...

Page 27: ...umber in white is the input number and the number in black is the output number SDI Input Output Serial digital inputs and outputs are via HD BNC connectors which terminate in 75 Ohms The number of connectors varies according to the actual module variant in use Connectors are color coded for easy identification Black shading indicates an input Gray shading indicates a bi directional connector see ...

Page 28: ...28 Connections SDI SFP ...

Page 29: ... input status There is one LED per input When Green Input enabled signal valid When Yellow Input disabled or Reclocker Bypass active When Red No signal on input or signal not valid See Input Output Input Output SFP on page 35 for information on enabling disabling inputs ...

Page 30: ...30 Rear Panel LEDs ...

Page 31: ...ess to any of the pages Setting Values Many of the settings within the templates have values either alpha or numeric When setting a value in a field the value whether text or a number must be saved by pressing the ENTER key or clicking the Save Value button Clicking an associated Preset Value button returns the value to the factory default setting Note The IQSDA41 42 will dynamically configure its...

Page 32: ...utput SFP see page 35 Logging Misc see page 39 Logging Input see page 41 Logging Output 1 n see page 43 RollTrack see page 45 Memory 1 16 see page 48 Information Window The Information window is displayed at the top of each page next to the pages list It can displays basic information about the input and output status of the module select a radio button as required ...

Page 33: ...and apply names to inputs and outputs The following information is displayed Product Name of the module Software Version Currently installed software version number Serial No Module serial number Build Factory build number This number identifies all parameters of the module OS Operating system version number PCB Printed Circuit Board revision number PCB Mods PCB modification level These controls a...

Page 34: ... to be reset to their factory defaults Input Names These are the input names displayed in logs To change the name of an input type the name in the appropriate text field and click S To return the name to its factory default click P Output Names These are the output names displayed in logs To change the name of an output type the name in the appropriate text field and click S To return the name to ...

Page 35: ...of an input error Configuration This allows the input configuration to be selected use the radio buttons to select the required input output configuration Note If SFPs are fitted the page is named Input Output SFP Note The options available are dependent on the number and type of input connectors on the module The other controls displayed on the page may also vary depending on the option selected ...

Page 36: ...l check boxes can be set or cleared simultaneously using the Set All and Clear All buttons Incoming signals at rates not selected here will be muted Reclocker Bypass Enabling Reclocker Bypass will prevent any incoming signal from being re clocked regardless of other settings The signal will be passed onwards without modification Outputs Each output can be muted individually Select Mute to manually...

Page 37: ...ected to the module SFP Details Displays technical details read from the SFP fitted to the module Configure Types When set to Auto the module interrogates the SFP and automatically selects the correct TxRx and Media types Alternatively settings may be selected manually if required ...

Page 38: ...FP Output n Displays transmission statistics read from the SFP fitted to the module SFP Input n Displays power statistics read from the SFP fitted to the module Restart Click Restart to power cycle the module This is required if the SFP type is changed ...

Page 39: ...igits Note this cannot be deselected OS_VERSION Reports the operating system name and version BUILD_NUMBER Reports the build number HARDWARE_VERSION Reports the hardware version number HARDWARE_MOD Reports the hardware modification number ROL_STATES Reports the RollCall status Valid values are OK FAIL n where n is the RollTrack index or indices which are failing Disabled LAST_RECALLED_MEMORY Repor...

Page 40: ...ging Misc UPTIME Reports the time since the last restart in the format ddd hh mm ss POWER_USAGE Displays the power rating for the module This is not a live power reading but rather a maximum rating Note this cannot be deselected Log Field Description ...

Page 41: ...rmation The following options are available Enable check boxes to activate log fields as required Log Field Description INPUT_N_STATE Reports current state of the input signal Valid values are OK input signal good FAIL input signal not detected INPUT_N_SDIRATE Reports current bit rate for the input ...

Page 42: ... input number INPUT_N_TYPE Reports current input type Valid values are HD SD 3G 6G 12G SDI INPUT_N_IDENT Reports system defined identifier for the input based on the rear ID INPUT_N_NAME Reports name of the input as defined on the Setup page See page 33 Log Field Description ...

Page 43: ...mation for each output The following options are available Enable check boxes to activate log fields as required Log Field Description OUTPUT_N_STATE Valid values are OK output signal good FAIL output signal not detected WARN Freeze WARN Pattern WARN Black OUTPUT_N_SDIRATE Reports current bit rate for the output ...

Page 44: ...utput 1 n SFP Where N is the input number OUTPUT_N_TYPE Valid values are HD SD 3G 6G 12G SDI OUTPUT_N_IDENT Name of the output as shown on the rear panel OUTPUT_N_NAME Reports name of the output as defined on the Setup page see page 33 Log Field Description ...

Page 45: ...elow the slider Clicking the P button selects the default preset value Source This enables selection of the source of information which is to trigger the transmission of data Clicking the P button selects the default preset value When no source is selected Unused is displayed Log Field Description User Memory 1 16 User defined Unused No RollTracks sent Input N OK Input N is good Input N LOST Input...

Page 46: ...ent to the selected destination unit The command may be changed by typing a code in the text area and then selecting the S button to save the selection Clicking the P button returns to the default preset command The RollTrack command consists of two sets of numbers for example 84 156 The first number 84 is the actual RollTrack command The second number 156 is the value sent with the RollTrack comm...

Page 47: ...gent Log Field Description OK RollTrack message was sent and received successfully Unknown RollTrack message has been sent but transmission has not yet completed Timeout RollTrack message has been sent but no acknowledgment received This could be because the destination unit is not at the location specified Bad RollTrack message has not been correctly acknowledged at the destination unit This coul...

Page 48: ...l the settings saved in a memory In the Recall Memory column select the memory to recall by clicking on it The recalled settings will be applied and the memory name will appear in the Last Recalled Memory section Save Memory This column lists the 16 pre set memory names that are available for use To save settings In the Save Memory column select a memory location and then click Save The current se...

Page 49: ...Last Recalled Memory pane displays the most recently recalled memory If any of the settings have been changed since it was recalled an asterisk will be displayed after the memory name Save Memory Name This option enables the preset memory names to be changed to something more memorable or meaningful if required To change a memory name In the Save Memory Name field type the new memory name and then...

Page 50: ...50 Operation Using the RollCall Control Panel Memory 1 16 ...

Page 51: ...ort www grassvalley com support Customers with a support contract should call their personalized number which can be found in their contract and be ready to provide their contract number and details Corporate Head Office Grass Valley 3499 Douglas B Floreani St Laurent Quebec H4S 2C6 Canada Telephone 1 514 333 1772 Fax 1 514 333 9828 www grassvalley com ...

Reviews: