background image

GUIDE TO INSTALLATION AND OPERATION 
 

SME-1901 / 1911 
 

Electromagnetic Compatibility 

 

This equipment has been tested for verification of compliance with FCC Part 15, Subpart B requirements for 

Class A digital devices. 

NOTE:

 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to 

part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference 

when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate 

radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful 

interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful 

interference in which case the user will be required to correct the interference at his own expense. 

 

 

This equipment has been tested and found to comply with the requirements of the EMC directive 

2004/108/CE: 

 

EN 55022 Class A radiated and conducted emissions 

 

EN 55024 Immunity of Information Technology Equipment 

 

EN 61000-3-2 Harmonic current injection 

 

EN 61000-3-3 Limitation of voltage changes, voltage fluctuations and flicker  

 

EN 61000-4-2 Electrostatic discharge immunity 

 

EN 61000-4-3 Radiated electromagnetic field immunity – radio frequencies 

 

EN 61000-4-4 Electrical fast transient immunity 

 

EN 61000-4-5 Surge immunity 

 

EN 61000-4-11 Voltage dips, short interruptions and voltage variations immunity 

 

 
 
 

 
 
 

 

 

Summary of Contents for GRASS VALLEY DENSITE Series

Page 1: ...GUIDE TO INSTALLATION AND OPERATION SME 1901 1911 SME 1901 SME 1911 Monitoring Streaming Media Encoders Guide to Installation and Operation M935 9900 130 2016 01 21...

Page 2: ...al may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct t...

Page 3: ...s 7 3 2 Card Edge Status LED 7 4 Local control using the Densit frame control panel 8 4 1 Overview 8 4 2 Menu for local control 8 5 Remote control using iControl 9 5 1 The iControl graphic interface w...

Page 4: ...GUIDE TO INSTALLATION AND OPERATION SME 1901 1911...

Page 5: ...ient design offers up to 20 streaming encoders per frame in Densit 3 High quality SDI distribution amplifier with up to six 3Gbps HD SD outputs SME 1901 Highly robust performance with bypass relay pro...

Page 6: ...GUIDE TO INSTALLATION AND OPERATION 2 SME 1901 1911 1 3 Functional Block Diagrams Figure 1 1 SME 1901 Functional Block Diagram Figure 1 2 SME 1911 Functional Block Diagram...

Page 7: ...t card edge of the SME 1901 1911 incorporates two elements Status LED see section 3 2 Select Button see section 4 The card extraction lever indicates the type of card that is installed SME 1901 shown...

Page 8: ...DA and fiber I O support SME 1901 3SRP D F Densit 3 Single slot width panel with 1x6 DA DIN connectors and fiber I O support SME 1911 rear connector panels SME 1911 DRP Densit 2 Double slot width pan...

Page 9: ...nstall the SME 1901 1911 card as follows 1 Open the front panel of the frame 2 Slide the SME 1901 1911 card into the slot and push gently on the handle to seat the connectors For the double slot width...

Page 10: ...ted line frame rate format 3G HD SD OUT Serial digital video outputs SME 1901 only The SME 1901 provides up to six 3G HD SD SDI video outputs on BNC or DIN 1 0 2 3 connectors labeled 3G HD SD OUT 1 to...

Page 11: ...The chart shows how the various error conditions that can be flagged on the SME 1901 1911 affect the LED state If a cell is gray the error condition cannot cause the LED to assume that state If more t...

Page 12: ...ard flashes yellow The local control panel displays a menu that can be navigated using the four pushbuttons located beside the display The functionality of the pushbuttons is as follows Used for menu...

Page 13: ...911 and the slot number where the card is installed in its Densit frame There are three main sections in the window itself identified in figure 5 1 Section 1 The top section displays eight icons on th...

Page 14: ...e can be used to operate the card yellow Local card control active The card is being controlled using the Densit frame control panel as described in section 4 Any changes made using the iControl inter...

Page 15: ...put signal yellow Operation mode Color Bars place the color bars and tone test pattern on the streaming output yellow Operation mode Lipsync place the lipsync test pattern on the streaming output Icon...

Page 16: ...iber input connector on the rear panel This is only available with a F rear panel and an appropriate SFP module installed Input Status This section of the panel shows the status of the two inputs and...

Page 17: ...own AFD VLI WSS Teletext The presence of teletext data for page 1 and page 2 actual page numbers are shown in the data boxes is shown by the Presence and Subtitle icons 5 4 Dolby Metadata panel Input...

Page 18: ...nmix Manual Downmix Config Use the pulldowns to set up the details of the downmix Oper Mode select the downmix operating mode Manual Use the other four pulldowns in this section to set up the downmix...

Page 19: ...dB 4 5 dB 6 dB Mute LFE Mix Level sets the LFE channels downmix level to the selected value 10 dB 9 dB 7 5 6 dB 4 5 dB 3 dB 1 5dB 0 dB 1 5 dB 3 dB 4 5 dB 6 dB Mute The block diagrams below show the co...

Page 20: ...rticularly in film originated content Test Pattern Streaming output only The pulldown allows the user to select an internally generated test signal to replace the program signal at the SME 1901 1911 s...

Page 21: ...bps Low 352x480 352x576 1 Mbps Disabled Very high 352x256 352x288 1500 kbps Medium 352x256 352x288 500 kbps Very low 128x96 128x96 128 kbps Disabled There are limitations with 1080p i video that do no...

Page 22: ...TCP RTSP s packetization of TS and encapsulated into an RTP TCP connection The Main and Proxy streams each have the following parameters On Off use the pulldown to enable or disable the stream IP add...

Page 23: ...TS over TCP Main stream rtsp card IP hiProxy Proxy stream rtsp card IP loProxy The card IP is the card s IP Address from the Network Settings panel During the RTSP session the card will also send a U...

Page 24: ...ted User Preset into the SME 1901 or SME 1911 All parameter settings and values will be replaced by the contents of the selected User Preset Click Save to store the current parameter settings and valu...

Page 25: ...ved correctly the Transfer Status box on the right of the Copy profile from line will indicate Succeeded against a green background If the file was not saved for some reason the Transfer Status box to...

Page 26: ...rofile to line will indicate Working against a yellow background When the profile copy operation is complete the Transfer Status box on the right of the Copy profile to line will indicate Succeeded ag...

Page 27: ...of selected individual alarms to the status LED located on the front card edge The Card LED status is shown at the bottom of the alarm tree in the Status Name column Overall Alarm This column allows c...

Page 28: ...rm At the bottom of the window are several other controls Overall alarm and GSM contribution follow card LED Click in the checkbox to force the Overall alarm and GSM contribution to be identical to th...

Page 29: ...luded in an iControl environment certain information about the card should be available to the iControl system The user can enter labels and comments that will make this card easy to identify in a com...

Page 30: ...1911 is registered Add Force the iControl service for this SME 1901 1911 to register itself on a user specified Jini lookup service using the following syntax in the data box jini ip_address where ip...

Page 31: ...64 high profile level 4 0 Frame rate Full rate of input signal except 3G is half the rate Bitrate 128 Kb s to 8 Mb s Audio encoding AAC LC MPEG 1 Layer II ELECTRICAL OUTPUTS 6 SME 1901 only Signal 3Gb...

Page 32: ...or 1 530 478 4148 To obtain a local phone number for the support center nearest you please consult the Contact Us section of Grass Valley s website www grassvalley com An online form for e mail conta...

Page 33: ...27MHz 3G 1080p60 A B B2 3G 1080p59 94 A B B2 SD 525 YC GFX 1600x1200 60 GFX 1920x1200 60 SD 625 HD 1080i50 HD 1080p25 HD 720p50 HD 720p25 SD 576p SD 625p50 SD 625p50 27MHz 3G 1080p50 A B B2 UNKNOWN E...

Page 34: ...LLOW RED FLASHING RED REPORT NONE GPI ELECT NO LOCK LEVEL GREEN YELLOW RED FLASHING RED REPORT NONE GPI OPTIC NO LOCK LEVEL GREEN YELLOW RED FLASHING RED REPORT NONE GPI SFP RX PWR WARN LEVEL GREEN YE...

Page 35: ...from Grass Valley and save it on your computer For version X Y Z it will be named SME 1901 vXYZ iControl_upgrade_package zip for SME 1901 SME 1911 vXYZ iControl_upgrade_package zip for SME 1911 Recomm...

Page 36: ...OFF This will accelerate the upgrade procedure It is not necessary to set all the Codec presets to DISABLED in the Codec Config panel 3 Close the SME 1901 SME 1911 control panel by clicking the icon...

Page 37: ...gress the card LED is Yellow When the upgrade has been completed the window will display the message Upgrade succeeded on a green background Look at the Installed package Installed firmware and Instal...

Page 38: ...Solo v4 or higher to execute the stand alone version Enter the Densit frame s IP address in the Densite IP address box and click Connect Click Open and choose the upgrade package The Upgrade Version...