BAIS-T™ CONFIGURATOR MODULE
30
Belanger , Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681
1MANUL051
Programming
Edit System Data (Screen 6)
Press the <ENTER> key. The following screen will appear:
Cnt: Triggered from the trap door limit switch, AnJam: Not used, Fixd: Fixed distance according to dollie spacing.
Press the <ENTER> key. The following screen will appear:
Btn: Activated from separate button, Tire: Activated from a tire treadle, Auto: Activated from the Operators Module.
Press the <ENTER> key. The following screen will appear:
Tells the system how long after the call method has been activated before the dollie ramp actually comes up.
Press the <ENTER> key. The following screen will appear:
Here you will assign the length of the Conveyor Dollie Count or the distance in which the ramp will remain up.
Make sure you SAVE after each option has been programmed. Review you programming frequently.
CAR WASH SET UP
12. Dollie Count
: 0000
0=Cnt 1=AnJam 2=Fixd
<Enter><Menu><Up/Dn>
CAR WASH SET UP
13. Doll Call Meth
: 0000
1=Btn 2=Tire 3=Auto
<Enter><Menu><Up/Dn>
CAR WASH SET UP
14. Dollie Delay
: 0000
Time In 1/4 Seconds
<Enter><Menu><Up/Dn>
CAR WASH SET UP
15. DollCountLen
: 0000
Distance Units
<Enter><Menu><Up/Dn>
Screen Key:
•
Line 2: Enter either 0, 1 or 2
Screen Key:
•
Line 2: Enter either 1 ,2 or 3
Screen Key:
•
Line 2: Enter desired running time in units