belfuse.com/power-solutions
BCD20021-G Rev AF, 29 November 2021
Page 9 of 26
X Series
375, 500 Watt AC-DC and DC-DC DIN-Rail Converters
© 2021 Bel Power Solutions & Protection
Table 6b: Output data of 500 Watt single-output standard models. General conditions as per table 6a.
Model
LXN1601
LXN1701
LXN1801
Unit
Characteristics
Conditions
min
typ
max
min
typ
max
min
typ
max
V
o nom
Output voltage nominal
1
V
i nom
,
I
o nom
24.25
24.7
25.2
36.37
37.05
37.8
48.5
49.4
50.4
V
*
24.55
24.7
24.85
36.82
37.05
37.28
49.1
49.4
49.7
V
o worst
Output voltage range of
tolerance
V
i min
–
V
i max
,
I
o
= (0.1 –
1)
I
o nom
24.0
25.8
36.0
38.7
48.0
51.6
V
o L
Overvoltage protection
28.5
30
42.75
45
57
60
P
o nom
Nominal output power
V
i
= 100 V –
V
i max
494
497
494
W
I
o nom
Output current nominal
V
i
= 100 V –
V
i max
20
13.4
10
A
I
o L
Output current limit
3
V
i
= 100 V –
V
i max
20.1
22.8
13.5
15.2
10.1
11.4
I
op
Output current boost
4
typ. 1 s
30
20
15
Ripple and noise
V
i
= 230 VAC,
f
i
= 50 Hz,
I
o nom
100
100
100
mV
pp
2
1100
2
1200
2
1200
2
∆
V
o u
Static line regulation
100 VAC
–
V
i max,
I
o nom
±0.1
±0.15
±0.15
V
∆
V
o I
Static load regulation
(droop)
V
i nom,
I
o
= (0.1 –
1)
I
o nom
–0.4
–0.6
–0.8
v
od
Dynamic load regulation
Voltage deviation
Recovery time
V
i nom,
I
o
=
(0.5
↔
1)
I
o nom
±1.2
±1.5
±1.8
40
80
80
ms
α
vo
Temperature coefficient
T
C min
– T
C max
±0.02
±0.02
±0.02
%/K
t
or
Start-up time
V
i
=
0
→
V
i nom,
I
o nom
700
700
700
ms
t
oh min
Hold-up time
I
o nom,
V
o nom
→
0.8
V
o nom
15
20
25
Table 6c: Output data of 500 Watt double-output models. General conditions as per table 6a.
Model
LXN2660
LXN2770
LXN2880
Unit
Characteristics
Conditions
min
typ
max
min
typ
max
min
typ
max
V
o nom
Output voltage nominal
1
V
i nom
,
I
o nom
24.25
24.7
25.2
36.37
37.05
37.8
48.5
49.4
50.4
V
*
24.55
24.7
24.85
36.82
37.05
37.28
49.1
49.4
49.7
V
o worst
Output voltage range of
tolerance
V
i min
–
V
i max
,
I
o
= (0.1 –
1)
I
o nom
24.0
25.8
36.0
38.7
48.0
51.6
V
o L
Overvoltage protection
28.5
30
42.75
45
57
60
P
o nom
Nominal output power
V
i
= 100 V –
V
i max
494
497
494
W
I
o nom
Output current nominal
V
i
= 100 V –
V
i max
2 x 10
2 x 6.7
2 x 5
A
I
o L
Output current limit
3
V
i
= 100 V –
V
i max
10.1
11.4
6.8
7.7
5.1
5.7
I
op
Output current boost
4
typ. 1 s
2 x 15
2 x 10
2 x 7.5
Ripple and noise
V
i
= 230 VAC,
f
i
= 50 Hz,
I
o nom
100
100
100
mV
pp
2
1100
2
1200
2
1200
2
∆
V
o u
Static line regulation
100 VAC
–
V
i max,
I
o nom
±0.1
±0.15
±0.15
V
∆
V
o I
Static load regulation
(droop)
V
i nom,
I
o
= (0.1 –
1)
I
o nom
–0.4
–0.6
–0.8
v
od
Dynamic load regulation
Voltage deviation
Recovery time
V
i nom,
I
o
=
(0.5
↔
1)
I
o nom
±1.2
±1.5
±1.8
40
80
80
ms
α
vo
Temperature coefficient
T
C min
– T
C max
±0.02
±0.02
±0.02
%/K
t
or
Start-up time
V
i
=
0
→
V
i nom,
I
o nom
700
700
700
ms
t
oh min
Hold-up time
I
o nom,
V
o nom
→
0.8
V
o nom
15
20
25
* Converters with version V105 or higher
1
Setting voltage with open R-input
2
Superimposed low frequency ripple at 2 •
f
i
3
Rectangular current limit characteristic (continuous operation)
4
Short-term peak power capability 150% of
P
o nom
for approx. 1 s