Exchange work
Illustration
Description / explanation
Power
Alarm
Service
TEST
5. Press the TEST button
[A]
on the control unit and hold
it for at least 5 seconds.
0
The green POWER LED flashes
6. Once the green POWER LED is permanently lit, release
the TEST button.
0
The “Remaining service time” counter (Modbus
address 3103 / 3104) is reset
0
The “Remaining switching cycles” counter (Modbus
address 3105 / 3106) is reset
7. Lay the control unit
[A]
carefully to one side.
8
8. If a design shell
[8]
is attached, carefully lift the design
shell
[8]
to the marked positions using a flat head
screwdriver.
9. Carefully remove the design shell
[8]
.
X3
9
10. Remove the hose connection
[9]
with the hose
[X3]
.
BEKOMAT
®
32iU
Original installation and operation manual
48 | 68