11/TR
Technical specifications
Inox
Glass
HIYG 640225 SXOP
HIYG 64225 SBOP
Burners
4 Gas Burner
4 Gas Burner
Voltage / frequency
220-240 V ~ 50-60Hz
220-240 V ~ 50-60Hz
Cable type / section
H05V2V2-F 3 x 0,75 mm2
H05V2V2-F 3 x 0,75 mm2
Cable length
maks. 1.5 m
maks. 1.5 m
Category of gas product
II 2ELS3B/P
II 2ELS3B/P
Gas type / pressure
NG G20/20 mbar
NG G20/20 mbar
Converting the gas type /
pressure
§
– optional
LPG G30-37 mbar
G2.350-13 mbar
LPG G30-37 mbar
G2.350-13 mbar
Rear left / Normal burner
1,75 kW
1,75 kW
Front left / Normal buner
1,75 kW
1,75 kW
Middle / Wok burner
3,3 kW
3,3 kW
Front right /
Auxiliary burner
1 kW
1 kW
Total gas consumption
7.8 kW
7.8 kW
Gas consumption NG G20/20 mbar
744 I/h
744 I/h
Gas consumption
LPG G30/37mbar
567 g/h
567 g/h
External dimensions (height /
width / depth)
99x580x510 mm
99x590x520 mm
Installation dimensions (width /
depth)
560 mm/490 mm
560 mm/490 mm
Technical specifications may be changed
without prior notice to improve the quality of
the product.
Figures in this manual are schematic and may
not exactly match your product.
Values stated on the product labels or in the
documentation accompanying it are obtained
in laboratory conditions in accordance with
relevant standards. Depending on operational
and environmental conditions of the product,
these values may vary.
Injector table
Hob zone
Auxiliary
burner
1 kW
Normal
burner
1.75 kW
Wok burner
(3.3 kW)
Gas type / Gas
pressure
G20/20 mbar NG
0,72 mm
0,97 mm
1,40 mm
G30/37mbar LPG
0,47 mm
0.65 mm
0,88 mm
G2.350 13 mbar
0,95 mm
1,28 mm
2,00 mm