42
Heatless Desiccant Dryers
|
Instruction Manual
Section 9:
Technical Data
Technical Data
Environmental Conditions
All dryers are designed to be safe under the following conditions:
• Indoor use
• Altitude up to 6560 ft.
• Ambient temperature 41°F (5°C ) to 104°F (40°C)
• Maximum RH 80% for temperatures up to 87.8°F (31°C), decreasing linearly to 50% RH at 104°F (40°C)
• Mains supply voltage fluctuations not to /- 10% of nominal
• Transient over voltage IEC 60664 Class II
• Pollution degree 2, IEC 60664
For operation extended from the above conditions, please contact the manufacturer.
Reference Conditions
Measurement
Performance
Effective inlet pressure
101.5 psig
7 barg
Effective inlet temperature
95°F
35°C
Relative humidity of air at inlet
95%
Pressure dewpoint, standard version
-40°F
-40°C
Specified Limitation for Operation
Measurement
Performance
Maximum inlet air pressure
232 psig
16 barg
Minimum inlet air pressure
58 psig
4 barg
Maximum ambient air temperature
122°F
50°C
Minimum ambient air temperature
41°F
5°C
Standard pressure dewpoint
-40°F
-40°C
Optional pressure dewpoint with application
of flow correction factor
-94°F
-70°C
Electrical supply voltage
100 VAC to 240 VAC
12 VDC to 24 VDC
Excessive vibrations from external sources may cause failure of this product.