7
- EN
Important:
C
There is no pump in the machine, so
ensure that the hose is placed to allow
a easy water flow.
C
The end of the hose should never be
higher than the level of the water outlet
on the machine. Otherwise, the “tank
full” light of your machine will illuminate
and stop the programme.
C
If the dryer is mounted on the washing
machine by means of a bracket, use of
the water drain hose is recommended.
The drain hose should be directed
downwards as shown in the figure.
Adjusting feet
In order to ensure that your product
operates more silently and vibration-
free, it must stand level and balanced on
its feet. Front feet of your product can
be adjusted. Balance the machine by
adjusting the feet.
1. Loosen the feet by hand.
2. Adjust the feet until the product stands
level and firmly on the floor.
C
Do not use any tools to loosen the
adjustable feet, otherwise, they can be
damaged.
C
Never remove the adjustable feet from
their housings.
2 plastic pieces supplied along with the
user manual prevent your machine from
slipping on wet and slippery surfaces. To
install the plastic parts:
1. Tilt your product to backwards.
2. Fit the plastic parts on to the front
adjustable feet. Press on the plastic
parts to snap them into their seating.
3. Check the balance of your product
again and readjust the adjustable feet if
necessary.
Electrical connection
Connect the machine to a grounded
outlet protected by a fuse of suitable
capacity as stated in the technical
specifications table. Our company shall
not be liable for any damages that will
arise when the machine is used on a
circuit without grounding.
• Connection must comply with national
regulations.
• If the current value of the fuse or
breaker in the house is less than 16
Amps, have a qualified electrician install
a 16 Amp fuse.
• Power cable plug must be within easy
reach after installation.
• The voltage and allowed fuse or
breaker protection are specified in the
“Technical Specifications” section.
• The specified voltage must be equal to
your mains voltage.
• Do not make connections via extension
cables or multi-plugs.
• The main fuse and switches must have
a contact distance of minimum 3 mm.
B
Damaged power cable must only be
replaced by a qualified electrician.
B
If the product is faulty, it must not be
operated unless it is repaired! There is
the risk of electric shock!
First use
• To have the product ready for operation
before calling the authorised service
agent, make sure that its location
and power supply installations are
appropriate. If they are not, call a
qualified electrician to have any
necessary arrangements carried out.
Summary of Contents for DC 1570
Page 1: ...DC 1570 Dryer Сушилня Sušilica Sušička ...
Page 21: ......
Page 39: ......
Page 57: ......
Page 75: ...75 CZ ...
Page 76: ...76 CZ ...