3.3 Circuit Diagram
The compressor doesn’t start.
Check if the resistance between the wire terminator of the compressor is good or not.
Usually, S-C 9secondary windings) is 2-10
Ω
; R-C( principal windings) is 2-6
Ω
.
Change the compressor
Check if the starting capacitor is OK. ( use a
AVOmeter to check and
AVOmeter can charge up or discharge.)
Change the starting capacitor.
Check if the compressor has voltage.
Check the electric wire
Change the compressor