background image

Pictograms and symbols

4

Service-Unit BEKOMAT® 32U Vario / 32U Vario F

Pos : 1 /Beko Tec hnisc he Dokumentati on/Ü bersc hriften/1/Pi ktogramme und Symbol e @ 1\mod_1290773595840_15098.doc x @ 20525 @ 1 @ 1

1

Pictograms and symbols

Pos : 2 /Beko Tec hnisc he Dokumentati on/Pi ktogramme/Anl eitung beac hten blau @ 0\mod_1213268300255_15098.doc x @ 15193 @ @ 1

Observe the installation and operating instructions

Pos : 3 /Beko Tec hnisc he Dokumentati on/Pi ktogramme/Anl eitung beac hten s/w T ypensc hild @ 1\mod_1290772180142_15098.doc x @ 20492 @ @ 1

Observe the installation and operating instructions
(on the type plate)

Pos : 4 /Beko Tec hnisc he Dokumentati on/Pi ktogramme/Gefahr Warnung Vorsic ht s/w @ 0\mod_1213265685174_15098.doc x @ 15189 @ @ 1

General danger symbol (danger, warning, caution)

Pos : 5 /Beko Tec hnisc he Dokumentati on/Pi ktogramme/G+W+ V N etz spannung s /w @ 0\mod_1213266193701_15098.doc x @ 15191 @ @ 1

General danger symbol (danger, warning, caution) for supply voltage and supply voltage-
carrying plants components

Pos : 6 /Beko Tec hnisc he Dokumentati on/Ü bersc hriften/1/Sic herheits hinweise @ 0\mod_1183637609261_15098.doc x @ 15102 @ 1 @ 1

2

Safety instructions

Pos : 7 /Beko Tec hnisc he Dokumentati on/Sic herheit/Hi nweis Anlei tung BEKO ( männl. N ame) @ 0\mod_1184147787557_15098.doc x @ 15120 @ @ 1

Please check whether or not these instructions correspond to the device type.

Adhere to all advice given in these operating instructions. They include essential information
which must be observed during the installation, operation and maintenance. Therefore it is
imperative for the service technician and the responsible operator / technical staff to read these
operating instructions prior to installation, start-up and maintenance.
The operating instructions must be accessible at any time at the place of application of the
BEKOMAT

®

32U Vario.

In addition to these operating instructions, local or national regulations must be complied with,
if necessary.
Make sure that the BEKOMAT

®

32U Vario is operated only within the permissible limit values

indicated on the type plate. Any deviation involves a risk for persons and materials, and may
result in malfunction and service failures.
If you have any queries regarding these installation- and operating instructions, please contact
BEKO TECHNOLOGIES CORP.

Pos : 8 /Beko Tec hnisc he Dokumentati on/Sic herheit/Gefahr Druc kluft @ 0\mod_1184148143854_15098.doc x @ 15121 @ @ 1

Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping
compressed air or through bursting plant components or plant components which are
not secured.

Pos : 9 /Beko Tec hnisc he Dokumentati on/Sic herheit/M aß nahmen Dr uc kl uft BM @ 0\mod_1184148284291_15098.doc x @ 15123 @ @ 1

Measures:

Do not exceed the maximum operating pressure (see type plate).

Only carry out service measures when the system is pressure less.

Use pressure-resistant installation material only.

The feed pipe must be tubed firmly. Discharge pipe: short, fixed pressure hose onto pressure-resistant
pipe.

Make sure that persons or objects cannot be hit by condensate or escaping compressed air.

Pos : 10 /Beko T ec hnis che D okumentati on/Sic her hei t/Gefahr Netzs pannung 1 s/w @ 0\mod_1184148186948_15098.doc x @ 15122 @ @ 1

Summary of Contents for BEKOMAT 32U Vario

Page 1: ...EN US english US Instructions for installation and operation Replacement unit Service Unit BEKOMAT 32U Vario 32U Vario F SUBM32UV SUBM32UVF 01 1723 ...

Page 2: ...2 Service Unit BEKOMAT 32U Vario 32U Vario F ...

Page 3: ...Service Unit BEKOMAT 32U Vario 32U Vario F 3 1 Pictograms and symbols 4 2 Safety instructions 4 3 Technical data 6 4 Control and maintenance 7 5 Elements and components 10 6 Recommended spare parts 11 ...

Page 4: ...nance Therefore it is imperative for the service technician and the responsible operator technical staff to read these operating instructions prior to installation start up and maintenance The operating instructions must be accessible at any time at the place of application of the BEKOMAT 32U Vario In addition to these operating instructions local or national regulations must be complied with if n...

Page 5: ...r permanent drainage Use genuine spare parts only This is imperative to ensure perfect functioning Pos 13 Beko Technische D okumentati on Sicher hei t Zusatz Sicherheitshi nweise BM31 32 SA 31U 32U SA 0 mod_1185351496993_15098 docx 15150 1 Additional advice The removed control unit has no IP degree of protection During installation use spanner flat at the feed pipe wrench size SW27 as a back rest ...

Page 6: ...T o Leistg 5 mod_1358843578945_15098 docx 30477 1 min max operating pressure see type plate 0 8 16 bar 12 230 psi or 1 2 16 bar 17 230 psi min max temperature see type plate 1 60 C 34 140 F or 1 70 C 34 158 F Condensate inflow NPT G internal max screw in depth 13 5 mm Condensate outflow G Ø 8 10 mm hose connector Condensate oil contaminated oil free Housing aluminium plastic glass fibre reinforced...

Page 7: ...ge Pos 24 Beko Technische D okumentati on Sicher hei t Maßnahmen N etzspannung BM 31U 32U 33U 7 mod_1390467197804_15098 docx 38070 1 Measures During electric installations all regulations in force need to be adhered to e g VDE 0100 IEC 60364 When the control unit is open service and installation works must only be undertaken when the system is deactivated The removed control unit has no IP degree ...

Page 8: ... cleaners Please note that condensates may contain aggressive or harmful components Therefore skin contact should be avoided Condensate is subject to mandatory waste disposal As such it must be collected in suitable containers and disposed of or processed properly Pos 28 Beko Technische D okumentati on Wartung BEKOM AT Wartung BM 31U 32U Ser vice Uni t 5 mod_1358510276825_15098 docx 30439 1 1 Prio...

Page 9: ...l designation and color of the arresting hook 2 Check whether or not the sealing mat 11 or the sensor tube plate 14 with contact springs 13 are clean dry and free from impurities 3 Introduce the sensor 12 into the sensor tube plate 14 4 Hang the hook 15 of the control unit 1 in the sensor tube plate 14 5 Press the control unit 1 against the service unit 5 and snap into place Start up subsequent to...

Page 10: ...ponenten BEKOMAT Bauteil e BM 32U Ser vice U nit 6 mod_1378727891522_15098 docx 33669 1 1 Screw 3 5 x 10 2 Upper part of the cover 3 Moulded gasket 4 Printed circuit board 5 Sensor 6 Lower part of the cover 7 Cable bushing 8 Sealing mat 9 Service unit 10 Hose connector 11 O ring 20 x 2 12 Intermediate adapter 13 Screw M6 x 12 14 O ring 14 x 1 78 15 Angle adapter 16 Design shell 17 Cord packing onl...

Page 11: ...r BM32V or BM32VBI Service unit Vario SUBM32UVF for BM32UVF or BM32UVBIF or BM32UVIFBIF or BM32VF or BM32VBIF or BM32VIFBIF 8 9 11 4023572 4023573 Gasket kit 3 8 11 17 4024392 Design shell 16 4010167 Connection adapter 11 12 13 14 15 4010155 Not for BEKOMAT 32U Vario built in or BEKOMAT 32U Vario built in F Pos 35 Beko Technische D okumentati on Globale Texte Hinweis Ü bersetzg d Orig anl eitg 1 m...

Page 12: ...on and operating instructions 4 Installations und Betriebsanleitung 4 Instructions safety instructions 4 Intermediate adapter 10 L Lower part of the cover 10 M Maintenance 7 O Order number 11 P Piktogramme 4 Printed circuit board 10 Q Qualified personnel 5 7 R Recommended spare parts 11 S Safety instructions 4 Sensor 10 Service measures 4 7 Service unit 10 Sets of spare parts 11 Spare parts 5 11 S...

Page 13: ...Service Unit BEKOMAT 32U Vario 32U Vario F 13 ...

Page 14: ...14 Service Unit BEKOMAT 32U Vario 32U Vario F ...

Page 15: ...Service Unit BEKOMAT 32U Vario 32U Vario F 15 ...