Installation and Operation Manual
BEKOKAT
®
V01 / 11-043
25 / 88
2.3
Requirements for the site
The installation location must fulfil the following requirements:
The installation will be executed within a building.
The
BEKOKAT
®
must be protected from exposure to moisture.
The ambient temperature must not exceed the specifications on the rating plate.
Select a level, solid and vibration-free installation surface with a maximum inclination of
< 5% to all sides. The weight of the
BEKOKAT
®
must be taken into account when
selecting the surface.
Set up the converter so that the system is easily accessible from the sides and from the
top.
Ensure adequate ventilation and heat dissipation.
Maintain a safe distance to traffic routes when setting up the
BEKOKAT
®
.
The blow-off direction of the safety valve must be away from traffic routes. An
appropriate risk assessment must be carried out at the installation site.
Equip the system with suitable collision protection.
Ensure that no water or condensate can ingress into the
BEKOKAT
®
.
Install an easily accessible manual shut-off valve before and after the assembly unit.
The surrounding area must be free of aggressive, corrosive, caustic, toxic, flammable
or oxidising substances.
The intake area of the compressor must be free of aggressive, corrosive, caustic, toxic,
flammable or oxidising substances.