Installation and Operation Manual
BEKOKAT
®
66 / 88
V01 / 11-043
5.7
Notes on reactor temperature during operation
The following operating states can occur:
Reactor temperature T <+ 110 °C
Please check the following points:
Volume flow too high
Operating pressure too low
heating system failed
Set the se 150 °C for the reactor temperature
(see chapter 5.3.2)
Compliance with the heating time after shutdown.
Reactor temperature T <+ 180 °C
Please check the following points:
Volume flow deviating from the nominal data of the system
Operating pressure too small
Oil entry very high
Set the se 150 °C for the reactor temperature
(see chapter 5.3.2)
In these cases, a change in the reactor set point temperature is possible to minimise the
thermal load on the system and energy consumption.
The setpoint can be reduced in increments of 5 K to approx. + 140 °C (see chapter 5.3.2).
Please consult the
BEKO
TECHNOLOGIES service.
DANGER Reactor temperature> + 200 °C
shown on the display reactor temperature> + 200 °C
If the reactor temperature indicated on the display is> + 200 °C, and
there is a fault, e.g. it may have been caused by an increased oil input
into the
BEKOKAT
®
.
Commissioning of the
BEKOKAT
®
is only permitted after inspection and
approval by authorised skilled technical personnel.