7.

 

Start up 

7.1 

Setting the delivery rate 

The delivery rate can be set progressively via the setscrew (6, Fig.2) 

for the delivery rate within a range from 0,2 to 2,0 cm³/stroke. 

Normally the delivery rate is preadjusted to 2,0 cm³/stroke. Dimension 

Y determines the flow rate of the device (see Fig.3). 

 

Release lock nut (7, Fig.2) 

 

Set delivery rate via the setscrew (6, Fig.2) 

-

 

Turn clockwise to reduce the delivery rate; turn counter-

clockwise to increase it. 

-

 

One turn of the setscrew corresponds to 1 mm and approx. 
0,2 cm³/stroke 

 

Retighten lock nut. 

 

 
 

 

7.2 

Replacement of grease cartridge 

The device is filled with commercially available grease cartridges of type S. 

 

Observe utmost cleanness when changing the grease cartridge! 

 

Unscrew grease cartridge (20, Fig.2) counter-clockwise out of the pump housing (1, Fig.2). 

 

Dispose empty grease cartridge properly. 

 

Screw in the new cartridge clockwise into the pump housing. 

 

Air may have entered into the system through the grease cartridge replacement. The grease area must be bled after each 

grease cartridge replacement. 

7.3 

Ventilation (grease area) 

 

Ventilate the complete system after the start-up as well as after a grease cartridge exchange.  

 

Ventilation is done by operating the system in pressureless condition and with open system outlets. Remove the pressure line 

from the set screw (6, fig. 2). 

 

Operate the device until lubricant comes out of the pressure connection without air inclusions! 

7.4 

Ventilation (oil area) 

Ventilate the oil section of the device after each first- or reconnection of the hydraulic connection. 

 

Release ventilation screw (9, Fig.2) (it is not necessary to turn it out completely). 

 

Fill oil area until oil escapes through the ventilation screw. 

 

Retighten ventilation screw. 

Stroke 

setting „Y

“ in mm 

Delivery rate in cm³/stroke 

Fig.3 

Summary of Contents for HPM-2S

Page 1: ...Page 1 BEKA 2015 All rights reserved a product of Hydraulic pump HPM 2S Article no 2574 Revision 07 2015 Original operating and assembly manual BAL2574_Hydraulic_pump_HPM 2S_0715EN...

Page 2: ...ing residual risk 5 3 Intended use 6 4 Scope of warranty 6 5 Transport and storage 6 6 Assembly instructions 7 6 1 Line assembly 7 6 2 Hydraulic connection 7 6 2 1 Lubrication line 7 6 2 2 Hydraulic l...

Page 3: ...0 cm stroke Delivery rate regulation Regulation range infinitely to 9 mm length No of strokes 1 stroke per pulse at hydraulic connection Grease cartridges cartridge type S Grease cartridge capacity 40...

Page 4: ...e might result in device damage This term is used to point out particular details Instructions which are directly attached to the device have to be strictly observed and kept in readable condition 2 2...

Page 5: ...a must be disposed professionally and in correspondence to relevant legal provisions Polluted and contaminated surfaces have to be cleaned before maintenance Please wear protective equipment to that p...

Page 6: ...is used according to the regulations and under the following conditions Assembly connection and maintenance are carried out by authorized professional staff The device is only used according to the op...

Page 7: ...bserve that they are clean seamless and of precision steel Assemble the pipes professionally and free from distortion Pay attention to pressure tightness of fittings All components must be approved fo...

Page 8: ...ise out of the pump housing 1 Fig 2 Dispose empty grease cartridge properly Screw in the new cartridge clockwise into the pump housing Air may have entered into the system through the grease cartridge...

Page 9: ...eturn connection by default 8 2 Function All stated positions to Fig 2 page 7 At each pressurization with hydraulic oil X the supply piston 2 is moved to the left thus pressing together the pressure s...

Page 10: ...e level regularly and change cartridge as necessary see chapter start up Lubricant change has to be done according to the specifications of the lubricant manufacturer Environmental influences like inc...

Page 11: ...ressure at the hydraulic connection Pressure spring broken Renew pressure spring Delivery rate adjusted to 0 0 cm stroke Adjust delivery rate Cartridge empty Change cartridge Sealing to cartridge leak...

Page 12: ...18 UNF F0619 05 03 001 6 1 Set screw F0619 06 04 7 1 Counter nut F0619 07 00 9 1 Ventilation screw M10x1 0802000255 10 1 Sealing ring A10x13 5x1 5 090760305121 11 1 Pressure spring D 40031 hydraulic...

Page 13: ...Page 13 BEKA 2015 All rights reserved a product of 14 Spare part drawing...

Page 14: ...Page 14 BEKA 2015 All rights reserved a product of 15 Dimensional drawing For technical details of the hydraulic connection A see chapter 1 Technical data...

Page 15: ...beka max de Our range of supply Gear pumps Multi line oil pumps Multi line grease pumps Single line central lubrication systems Dual line central lubrication systems Oil circulation central lubricatio...

Reviews: