![BEKA HPM-2S Original Operating And Assembly Manual Download Page 11](http://html1.mh-extra.com/html/beka/hpm-2s/hpm-2s_original-operating-and-assembly-manual_2723982011.webp)
Page
11 ©
BEKA 2015 All rights reserved!
...a product of
12.
Troubleshooting
Malfunction
Possible cause
Possible remedy
Pump does not deliver
lubricant
No hydraulic oil pressure at hydraulic
connection
Check the pressure at the hydraulic connection
Pressure spring broken
Renew pressure spring
Delivery rate adjusted to 0,0 cm³/stroke
Adjust delivery rate
Cartridge empty
Change cartridge
Sealing to cartridge leaky
Renew sealing
Counter pressure in lubrication system
too high (line rest pressure too high)
Check lubrication system
Lubricant quantity too
low or too high
Delivery rate adjusted wrong
Adjust delivery rate