BEKA HPM-2S Original Operating And Assembly Manual Download Page 5

 

 

 Page 

5 © 

BEKA 2015 All rights reserved! 

...a product of

2.4 Owner’s/Operators‘ 

obligations 

 

If movable, rotating, hot or cold parts of the device bear risks, these parts need to be secured against contact by 

the customer. This protection against contact must not be removed. 

 

Any leakages of hazardous substances must be drained in a way that no risks for persons or the environment 

arise. 

 

Keep to all legal provisions. 

 

Hazards due to electricity are to be excluded.  

 

Examination of pipes and hoses regarding safe provision, use, proper assembly and function has to be carried 

out according to regionally applicable directives. Inspection intervals may not be exceeded. 

 

Defective pipes or hoses must be replaced immediately and professionally. 

 

Hydraulic hoses and polyamide pipes are subject to a natural aging-process and thus have to be exchanged in 

regular intervals according to the manufacturer’s specifications. 

 

A safety data sheet of the currently used lubricant must be provided at the device.  

2.5 

Safety instructions for maintenance, inspection and assembly 

All  maintenance,  inspection and assembly work may only be carried out by qualified personnel who is 

sufficiently informed by thorough reading of the user information. 

Generally any work at the device may only be carried out at complete standstill and in pressureless as well as 
disconnected condition. Furthermore appropriate personal protective equipment (goggles among others) is 

necessary. The shutdown procedure of the device as described in the manual must be strictly followed. 

Secure the device against intentional or unintentional recommissioning during maintenance or repair. All safety and 

protection arrangements have to be put back in place again immediately after finishing work.  

Environmentally hazardous media must be disposed professionally and in correspondence to relevant legal 

provisions

Polluted and contaminated surfaces have to be cleaned before maintenance. Please wear protective 

equipment to that purpose. See the lubricant manufacturers‘ safety data sheets hereto, respectively the data sheets 

provided by the manufacturers of auxiliaries and working materials.  

Check the surface temperature of the device as a possible heat transfer bears the risk of burns. Wear heat resistant 

protective gloves! 

Open flame and fire are strictly forbidden during maintenance, inspection and repair due to fire hazard. 

2.6 

Unauthorized modification and production of spare parts 

Modification, repair and alterations of the device are only accepted after manufacturer feedback. Original spare 
parts
 and authorized accessories from the manufacturer contribute to safety. The use of other parts can result in the 

loss of any liabilities for the resulting consequences. BEKA does not assume liability for parts that are retrofit by the 

operator.  

2.7 

Inadmissible modes of operation 

The operational safety of the device is only guaranteed for appropriate application as indicated in the operating manual. Never 

exceed the limit values of the technical data.  

2.8 

General hazard warning – residual risk 

All components are designed according to valid regulations of the construction of technical systems in regards to 

operational safety and accident prevention. Independently from this the use can lead to hazards for the user or third 
parties as well as for other technical facilities. Therefore the device may only fulfill its intended use in a technically 

acceptable and faultless condition. This has to happen in adherence of the according safety regulations and under 

observance of the operating manual. Inspect  the device and its attachment parts regularly and check them for 

possible damage or leakagesLiquids could escape under high pressure from pressurized components which 
become leaky.  

Summary of Contents for HPM-2S

Page 1: ...Page 1 BEKA 2015 All rights reserved a product of Hydraulic pump HPM 2S Article no 2574 Revision 07 2015 Original operating and assembly manual BAL2574_Hydraulic_pump_HPM 2S_0715EN...

Page 2: ...ing residual risk 5 3 Intended use 6 4 Scope of warranty 6 5 Transport and storage 6 6 Assembly instructions 7 6 1 Line assembly 7 6 2 Hydraulic connection 7 6 2 1 Lubrication line 7 6 2 2 Hydraulic l...

Page 3: ...0 cm stroke Delivery rate regulation Regulation range infinitely to 9 mm length No of strokes 1 stroke per pulse at hydraulic connection Grease cartridges cartridge type S Grease cartridge capacity 40...

Page 4: ...e might result in device damage This term is used to point out particular details Instructions which are directly attached to the device have to be strictly observed and kept in readable condition 2 2...

Page 5: ...a must be disposed professionally and in correspondence to relevant legal provisions Polluted and contaminated surfaces have to be cleaned before maintenance Please wear protective equipment to that p...

Page 6: ...is used according to the regulations and under the following conditions Assembly connection and maintenance are carried out by authorized professional staff The device is only used according to the op...

Page 7: ...bserve that they are clean seamless and of precision steel Assemble the pipes professionally and free from distortion Pay attention to pressure tightness of fittings All components must be approved fo...

Page 8: ...ise out of the pump housing 1 Fig 2 Dispose empty grease cartridge properly Screw in the new cartridge clockwise into the pump housing Air may have entered into the system through the grease cartridge...

Page 9: ...eturn connection by default 8 2 Function All stated positions to Fig 2 page 7 At each pressurization with hydraulic oil X the supply piston 2 is moved to the left thus pressing together the pressure s...

Page 10: ...e level regularly and change cartridge as necessary see chapter start up Lubricant change has to be done according to the specifications of the lubricant manufacturer Environmental influences like inc...

Page 11: ...ressure at the hydraulic connection Pressure spring broken Renew pressure spring Delivery rate adjusted to 0 0 cm stroke Adjust delivery rate Cartridge empty Change cartridge Sealing to cartridge leak...

Page 12: ...18 UNF F0619 05 03 001 6 1 Set screw F0619 06 04 7 1 Counter nut F0619 07 00 9 1 Ventilation screw M10x1 0802000255 10 1 Sealing ring A10x13 5x1 5 090760305121 11 1 Pressure spring D 40031 hydraulic...

Page 13: ...Page 13 BEKA 2015 All rights reserved a product of 14 Spare part drawing...

Page 14: ...Page 14 BEKA 2015 All rights reserved a product of 15 Dimensional drawing For technical details of the hydraulic connection A see chapter 1 Technical data...

Page 15: ...beka max de Our range of supply Gear pumps Multi line oil pumps Multi line grease pumps Single line central lubrication systems Dual line central lubrication systems Oil circulation central lubricatio...

Reviews: