Assembly instructions
Check the device for possible transport damage and for completeness before the assembly. Any installed equipment for
transportation safety has to be removed.
Comply with the following conditions for assembly of the device in order to obtain a properly built together machine of
all parts without compromise of safety or persons’ health:
Assemble the device in balance on the installation location in order to ensure safe operation. Observe the information on the
fastening holes given in the dimensional drawing. When selecting the set-up location, please mind that the device should be
protected against ambiental and mechanic influences. Ensure full access, e.g. for the grease cartridge change.
Special measures concerning noise prevention or oscillation reduction do not have to be taken.
6.1 Line
assembly
Professional layout!
When using pipes, observe that they are clean, seamless and of precision steel!
Assemble the pipes professionally and free from distortion!
Pay attention to pressure tightness of fittings!
All components must be approved for max. operating pressure (see technical data).
Pay attention to a sufficient dimensioning of the return lines and decline of the pipelines from the lube points to the device (at
least 5 %).
6.2 Hydraulic
connection
Hydraulic connection must be assembled by a qualified specialist!
Compare the existing hydraulic pressure with the stated min. and max. operating pressure!
The hydraulic connection needs to be carried out referring to the instructions of these assembly instructions.
6.2.1 Lubrication
line
A high-pressure hose with hose connections has to be mounted into the connection at the lubrication outlet (W, Fig.2) for the
lubrication line.
6.2.2 Hydraulic
line
Put a bypass line from the hydraulic system of the carrier unit to the hydraulic connection of the device (X, Fig.2)
This line has to be relieved to drain surplus oil from the hydraulic pressure chamber in the reservoir during
the lubrication supply.
Note!
Fig.2