Assembly instructions 

Check the device for possible transport damage and for completeness before the assembly. Any installed equipment for 

transportation safety has to be removed.  

Comply with the following conditions for assembly of the device in order to obtain a properly built together machine of 
all parts without compromise of safety or persons’ health:  

 

 

Assemble the device in balance on the installation location in order to ensure safe operation. Observe the information on the 
fastening holes given in the dimensional drawing. When selecting the set-up location, please mind that the device should be 

protected against ambiental and mechanic influences. Ensure full access, e.g. for the grease cartridge change.   

Special measures concerning noise prevention or oscillation reduction do not have to be taken.  

6.1 Line 

assembly 

 

Professional layout! 

 

When using pipes, observe that they are clean, seamless and of precision steel! 

 

Assemble the pipes professionally and free from distortion! 

 

Pay attention to pressure tightness of fittings! 

 

All components must be approved for max. operating pressure (see technical data).  

 

Pay attention to a sufficient dimensioning of the return lines and decline of the pipelines from the lube points to the device (at 

least 5 %).  

6.2 Hydraulic 

connection 

 

Hydraulic connection must be assembled by a qualified specialist! 

 

Compare the existing hydraulic pressure with the stated min. and max. operating pressure! 

 

The hydraulic connection needs to be carried out referring to the instructions of these assembly instructions. 

6.2.1 Lubrication 

line 

A high-pressure hose with hose connections has to be mounted into the connection at the lubrication outlet (W, Fig.2) for the 

lubrication line. 

6.2.2 Hydraulic 

line 

Put a bypass line from the hydraulic system of the carrier unit to the hydraulic connection of the device (X, Fig.2) 

This line has to be relieved to drain surplus oil from the hydraulic pressure chamber in the reservoir during 
the lubrication supply.  

 

Note! 

Fig.2 

Summary of Contents for HPM-2S

Page 1: ...Page 1 BEKA 2015 All rights reserved a product of Hydraulic pump HPM 2S Article no 2574 Revision 07 2015 Original operating and assembly manual BAL2574_Hydraulic_pump_HPM 2S_0715EN...

Page 2: ...ing residual risk 5 3 Intended use 6 4 Scope of warranty 6 5 Transport and storage 6 6 Assembly instructions 7 6 1 Line assembly 7 6 2 Hydraulic connection 7 6 2 1 Lubrication line 7 6 2 2 Hydraulic l...

Page 3: ...0 cm stroke Delivery rate regulation Regulation range infinitely to 9 mm length No of strokes 1 stroke per pulse at hydraulic connection Grease cartridges cartridge type S Grease cartridge capacity 40...

Page 4: ...e might result in device damage This term is used to point out particular details Instructions which are directly attached to the device have to be strictly observed and kept in readable condition 2 2...

Page 5: ...a must be disposed professionally and in correspondence to relevant legal provisions Polluted and contaminated surfaces have to be cleaned before maintenance Please wear protective equipment to that p...

Page 6: ...is used according to the regulations and under the following conditions Assembly connection and maintenance are carried out by authorized professional staff The device is only used according to the op...

Page 7: ...bserve that they are clean seamless and of precision steel Assemble the pipes professionally and free from distortion Pay attention to pressure tightness of fittings All components must be approved fo...

Page 8: ...ise out of the pump housing 1 Fig 2 Dispose empty grease cartridge properly Screw in the new cartridge clockwise into the pump housing Air may have entered into the system through the grease cartridge...

Page 9: ...eturn connection by default 8 2 Function All stated positions to Fig 2 page 7 At each pressurization with hydraulic oil X the supply piston 2 is moved to the left thus pressing together the pressure s...

Page 10: ...e level regularly and change cartridge as necessary see chapter start up Lubricant change has to be done according to the specifications of the lubricant manufacturer Environmental influences like inc...

Page 11: ...ressure at the hydraulic connection Pressure spring broken Renew pressure spring Delivery rate adjusted to 0 0 cm stroke Adjust delivery rate Cartridge empty Change cartridge Sealing to cartridge leak...

Page 12: ...18 UNF F0619 05 03 001 6 1 Set screw F0619 06 04 7 1 Counter nut F0619 07 00 9 1 Ventilation screw M10x1 0802000255 10 1 Sealing ring A10x13 5x1 5 090760305121 11 1 Pressure spring D 40031 hydraulic...

Page 13: ...Page 13 BEKA 2015 All rights reserved a product of 14 Spare part drawing...

Page 14: ...Page 14 BEKA 2015 All rights reserved a product of 15 Dimensional drawing For technical details of the hydraulic connection A see chapter 1 Technical data...

Page 15: ...beka max de Our range of supply Gear pumps Multi line oil pumps Multi line grease pumps Single line central lubrication systems Dual line central lubrication systems Oil circulation central lubricatio...

Reviews: