23
Display
Summary of function
di5P-2
Lower display
Configures the lower display to show
set time
5Et t
or, when the
CYCLE5
repeat function is activated, the restart
delay count-down plus the cycle count
number.
With
CYCLE5
not enabled:
Select
Lower display shows
5td
Set time
5et t
oFF
Disables lower display.
See section 6.5.7
With
CYCLE5
enabled:
Select
Lower display shows
5td
Cycles requested and
cycles performed with
time-down shown during
requested delay period.
Brief notification of timer
status i.e.
CYCLE
or
dELAY
at start of each
period.
LAbEL
Exactly as
5td
but with
periodic notification of
timer status i.e.
CYCLE
or
dELAY
.
oFF
Disables lower display.
See section 6.5.7
5tAr5toP
Starting and stopping the timer
Defines how the Timer is started and
stopped.
Start
Stop
LoCAL
&
button
*
button
ControL 1
Input high
Input low
ControL 2
Input low
Input high
High and low inputs are specified for a
continuous voltage input. For other
types of sensor input.
See section 6.5.8
Display
Summary of function
unit5
Units of display
Selects displayed units.
1
2 : 00 : 00
Hours, minutes & seconds
12 : 00
Hours & minutes
*
30 : 00
Minutes & seconds
30
Seconds
Excludes delay of optional control
outputs which is always shown in
seconds and the grand total which is
always shown in hours.
*
Only available if
5et t
and
r5t dELA
,
if already entered, specify zero
seconds or seconds which are exactly
divisible by sixty.
See section 6.5.9
5Et t
Set time
When controlling an external event via
the optional control outputs the
BA377E will
time-down
from the set
time to zero or
time-up
from zero to the
set time.
Note:
Timer will only start if a non zero
value is entered for set time
5et t
.
See section 6.5.10
CYCLE5
Repeat timing cycle
Contains a sub-menu with three sub-
functions,
EnbL
,
CYCL Cnt
and
r5t
dELA
.
See section 6.5.11
Cycle function enable
EnbL
Enables or disables the
cycle5
function without changing the
parameters.
See section 6.5.12
Cycle count
CYCL Cnt
Defines the number of times that the
timer cycle is repeated.
See section 6.5.13
Restart delay
r5t dELA
Defines the time delay between timer
cycles.
See section 6.5.14
AC5Et t
Access
5Et t
and
r5t dela
from
display mode.
Enables
5Et t
and
r5t dela
to be
adjusted from the display mode. Also
contains a sub-function
ACCd
which
defines a separate code to protect
access from the display mode to
5Et t
and
r5t dela
.
See section 6.5.15
Summary of Contents for BA377E
Page 1: ...Issue 6 4th May 2021 BA377E Single input Intrinsically safe Timer or Clock Issue 6...