6.4.1
Altering seam-specific parameters
Needle feed (with cylinder)
Via this parameter the needle feed is set.
Parameter 01:
Line 1
Number of stitches until the needle feed engages
Setting range:
0 - 2000
Parameter 02:
Fullness line 1 ON/ OFF
Setting range:
0 / 1
Parameter 03:
Line 2
Number of stitches how long the needle feed is
engaged
Setting range:
0 - 2000
Parameter 04:
Fullness line 2 ON/ OFF
Setting range:
0/1
Parameter 05:
Line 3
Number of stitches how long the needle feed is
engaged
Setting range:
0 - 2000
Parameter 06:
Fullness line 3 ON/ OFF
Setting range:
0/1
Needle feed (with step motor)
Via this parameter the needle feed with step motor drive is set.
Parameter 01:
Line 1
Number of stitches
Setting range:
0 - 2000
Parameter 02:
Fullness in line 1
Setting range:
0 - 2000
Parameter 03:
Line 2
Number of stitches
Setting range:
0 - 2000
Parameter 04:
Fullness in line 2
Setting range:
0 - 2000
Parameter 05:
Line 3
Number of stitches
Setting range:
0 - 2000
Parameter 06:
Fullness in line 3
Setting range:
0 - 2000
27