The  installation  of  the  detector  does  not  exempt  from  the  compliance  with  all  regulations  concerning  the  characteristics,
installation  and  use  of  gas  appliances.  The  ventilation  of  the  spaces  and  the  elimination  of  combustion  products  are  described
in  the  UNI  norms  according  to  ART.  3  LAW  1083  /  71  and  relevant  legal  provisions.

Compatible  control  units

MAINTENANCE

The user periodically (every 6 months) must perform a check of the operation of the control unit by spraying

a suitable test gas at the base of the probes connected until the alarm condition is reached.

• At least once a year make a more accurate check by a specialist technician.

• Disabling the detector must be carried out by qualified personnel.

Side View

60  mm

80  mm

8

0

 mm

Rearward   View

Foro  6,5  mm

100  mm

1

0

0

 

mm

4

0

 mm

Front View

CONTROL UNITS

             MOUNTING

PROBES Max.    DEGREE         PRE

  ALARMS      POSITIVE      OPERATING

  protec.        alarms

                       safety           range

GS100M unit 1 zone

            Wall/cabinet

1

I P 4 4

2

1

Y E S

N O

GS300M unit 1 zone

Wall/cabinet

3

I P 4 4

2

1

Y E S

N O

GS300-Mc unit 1 zone

Wall/cabinet

3

I P 4 4

2

1

Y E S

N O

BX444-MC unit 1 zone

Wall/cabinet

4

I P 4 4

2

1

Y E S

N O

BX150 unit  1 zone

Panel

            1

I P 4 2

1

1

Y E S

N O

BX180 unit  1 zone

Omega  bar  DIN

1

I P 2 0

1

1

Y E S

N O

BX280 unit  1 zone

Omega  bar  DIN

2

I P 2 0

1

1

Y E S

N O

BX449F unit 1 zone

            Omega bar DIN4

I P 2 0

1

1

Y E S

N O

BX308 unit  1 zone

            Omega bar DIN8

I P 2 0

1

1

Y E S

Y E S

BX308/Box  unit 1 zone

Wall

            8

I P 6 5

1

1

Y E S

Y E S

BX316 unit  2 zones

            Barra Omega

            16

I P 2 0

1

2

Y E S

Y E S

BX316/Box unit  2  zones

Wall

            16

I P 6 5

1

2

Y E S

Y E S

TAKITJ8 * Data Collector

Wall

             8

I P 6 5

-

-

-

-

Summary of Contents for SGM595/A

Page 1: ...rotection that together with one of BE INAT s industrial type Control Units detects the presence of esplosive gas such as Methane LPG Hydrogen and other types of gas The probe is managed by a microprocessor which not only supplies an alarm signal to the control unit connected to it but also allows execution of a self diagnosis and therefore an AUTOMATIC CALIBRATION in order to always have the maxi...

Page 2: ...TATIONS The installation of the SGM595 A Sensor its ordinary and extraordinary maintenance every six months and its out of service removal at the end of the functional life guaranteed by the manufacturer must be carried out by authorized or specialized personnel Do not allow it to become wet The control unit can be seriously damaged as it is not waterproof either when immersed in water or exposed ...

Page 3: ...ed personnel Side View 60 mm 80 mm 80 mm Rearward View Foro 6 5 mm 100 mm 100 mm 40 mm Front View CONTROLUNITS MOUNTING PROBES Max DEGREE PRE ALARMS POSITIVE OPERATING protec alarms safety range GS100M unit 1 zone Wall cabinet 1 I P 4 4 2 1 Y E S N O GS300M unit 1 zone Wall cabinet 3 I P 4 4 2 1 Y E S N O GS300 Mc unit 1 zone Wall cabinet 3 I P 4 4 2 1 Y E S N O BX444 MC unit 1 zone Wall cabinet 4...

Page 4: ...ow The probe detects an anomaly FAULT 1 2 3 4 5 6 C NO C NO C NO Fault Relay Pre Allarme Relay Main Alarm Relay Optional Relay Board CARD03 Linear Output 4 20 mA 100 20 100 20 SELECTION OF THE OPERATING RANGE The Conventional Probes NOT SUITABLE IN ATEX ZONE LEAVE THE FACTORY WITH A DEFAULT OPERATING RANGE VALUE SET AT 20 OF THE LEL To select the operation range to 100 LEL you need to move the jum...

Page 5: ...irectly WARNING These measurement should be performed in clean air Moreover this test must be performed only with the probe connected to a control unit or with a 220 Ohm resistance installed between terminal 2 and terminal 3 Linear Otput 4 20 mA 3 2 1 R 0 1 3 2 1 1 VDC Voltmeter Power Supply 12 24 V Troubleshooting before calling a technician Display legend Displays the type of probe or device Dis...

Page 6: ... controlled boiler burner industrial kitchens etc but on the opposite side 2 The probes must not be affected by fumes vapors and by sources of moving air which could distort the detection 3 The probes must not be installed near sources of heat fans or vacuum cleaners NOTE Recall that the GAS detection sensors placed inside the probe are perishable components whose average duration is variable 5 ye...

Page 7: ...e of gas presence cannot be found or removed abandon the building and call the emergency services when outside fire department distributors etc IMPORTANT The operation test should not be carried out with the gas tap as this does not guarantee a sufficient concentration to activate the general alarm Warning If you have the following symptoms vomiting sleepiness or else go to the closest first aid s...

Page 8: ...es points in case you buy a new and similar product local collection points waste collection center local recycling center etc By ensuring this product is disposed of correctly you will help prevent potential negative consequence for the environment and human health which could otherwise be caused by inappropriate waste handing of this product The recycling of materials will help to conserve natur...

Reviews: