3.3 Example Configuration
The stations are configured according to the table below. The settings made are
indicated by the corresponding LEDs. For configuration instructions, see
chapter
If two additional extended keyboards are added, configure the station numbers
3 and 4 in the same way as Station 2.
Keyboard
Station
number
Communication
speed
Communication
port
Pass through
messages
Station 1
1*
38,400 bps*
RS232C*
Enabled (F16 + F7)
Station 2
2 (F16 + F2) 38,400 bps*
RS485 (F16 + F15) Disabled*
* Default setting
RS232C (CAB5)
RS422
RS485
Operator terminal
X-Key 16, station 1
X-Key 16, station 2
Controller
Summary of Contents for X-Key 16
Page 1: ...X Key 16 Manual MAEN827B 2008 05 English Deutsch...
Page 4: ...Contents Beijer Electronics MAEN827B...
Page 20: ...Drawings 20 Beijer Electronics MAEN827B 8 Drawings 8 1 Outline Drawing...
Page 21: ...Drawings Beijer Electronics MAEN827B 21 8 2 X Key 16 Installation...
Page 22: ...Drawings 22 Beijer Electronics MAEN827B 8 3 Connection Drawing...
Page 23: ...Drawings Beijer Electronics MAEN827B 23 8 4 CAB5...
Page 24: ...Drawings 24 Beijer Electronics MAEN827B 8 5 CAB8...
Page 25: ...Drawings Beijer Electronics MAEN827B 25 8 6 Text Strips...
Page 28: ...Inhalt Beijer Electronics MADE827B...
Page 44: ...Zeichnungen 20 Beijer Electronics MADE827B 8 Zeichnungen 8 1 bersichtszeichnung...
Page 45: ...Zeichnungen Beijer Electronics MADE827B 21 8 2 Installation von X Key 16...
Page 46: ...Zeichnungen 22 Beijer Electronics MADE827B 8 3 Anschlusszeichnung...
Page 47: ...Zeichnungen Beijer Electronics MADE827B 23 8 4 CAB5...
Page 48: ...Zeichnungen 24 Beijer Electronics MADE827B 8 5 CAB8...
Page 49: ...Zeichnungen Beijer Electronics MADE827B 25 8 6 Textstreifen...