ELECTRICAL INSTALLATION  

The electrical installation should be carried out by qualified personal only, according to the 
regulations for electrical and mechanical safety in your country. 

VERY IMPORTANT: Check the user manual of the LED Manager for the maximum allowed power on 
its outputs! Do not exceed this maximum allowed power! To know the total power consumption of all 
LED products in a chain you simply have to count up the power consumption of all units in the chain. 
Check the chapter “specifications” at the end of this manual to see the power consumption of the 
different LED STRIPS! 

 Since the LED Manager uses special 4pin connecters on its power 

outputs, we suggest to buy an optional 1m extension cable (with 
special male/female 4pin connectors) and to cut the female connector. 
Now you can easily strip the cable. You will find 4 colored wires inside: 

 

White wire:

 This is the common wire (anode) 

 

Red wire:

 This the power for the red LEDs (max. 50W) 

 

Green wire:

 This the power for the green LEDs

 

(max. 50W) 

 

Blue wire:

 This the power for the blue LEDs (max. 50W) 

 Just connect these 4 wires to the corresponding 4 wires of the 

projector. All projectors can be connected in parallel as shown on the 
drawing below. Make sure not to exceed the maximum allowed load! 

 

 

 

 For longer distances you can extend the cables with a normal 4x1,5mm² 

electrical installation cable. If you can’t find a cable with the same color codes we 
strongly suggest you write down the color transitions between both cables! (ex. 
white 

Æ

 black, blue 

Æ

 blue, green 

Æ

 brown, …) This is extremely important 

otherwise the projectors will not work as expected. 

 When you install several projectors, you will surely need special waterproof 

junction boxes to make the junctions needed. 

  Another option is to open the waterproof metal enclosure (4) and to replace the 

original cable by your own cable. In this case you can make the connection 
immediately inside the projector so you don’t need a special waterproof junction 
box.  

  After checking that the maximum allowed power is not exceeded, you can connect the cable, coming from 

the projectors, to one of the outputs of the LED Manager. 

Example power calculation:

 You have to install 47x LED GROUND LIGHT 

Æ

 47x3W = 141Watt. This 

chain can be connected to one of the LED Manager outputs since it does not exceed the allowed 150W. The 
maximum number of Ground lights connected to the LED Manager = 2x 50pcs = 100pcs. 

 

 

ENGLISH  

OPERATION 

MANUAL 

 

 
JB SYSTEMS® 

4/20 

LED GROUND LIGHT 

OPERATING INSTRUCTIONS 

Since the LED Ground light is controlled by the LED Manager, we strongly advice to read the operation 
instructions in the LED Manager user manual. 
 
 

MAINTENANCE 

  Switch off the LED Manager and unplug the mains cable. 

During inspection the following points should be checked: 

  All screws used for installing the projector and any of its parts should be tightly fastened and may not be 

corroded. 

  When the glass cover is visibly damaged due to cracks or deep scratches, it must be replaced. 

  The cables must be in impeccable condition and should be replaced immediately when even a small 

problem is detected. 

  Check the cable glands and the sealing rubber around the glass cover if you see water on the inside of the 

projector. 

  The unit can be cleaned with the normal floor cleaning products. 

 

 
SPECIFICATIONS 

Connections: 

4 colored wires with “press on” connections 

IP-protection: 

IP67  

Operation voltage :

 24Vdc 

common 

anode 

Power consumption: 

3Watt (39 LEDs) 

Weight:

 1,5kg 

Size: 

see drawing below 

 

 

 

 

Every information is subject to change without prior notice 

You can download the latest version of this user manual on our website: www.beglec.com 

Summary of Contents for JB SYSTEMS LED GROUND LIGHT

Page 1: ...ontent in any manner without express permission of the publisher is prohibited LED GROUND LIGHT LED GROUND LIGHT LED RGB PASSIVE GROUND LIGHT P6 I 7 ROO WATERP F Version 1 1 Operation Manual Mode d emploi Gebruiksaanwijzing Bedienungsanleitung Manual de instrucciones EN FR NL DU ES ...

Page 2: ...t toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften DU ENTSORGUNG DES GERÄTS Entsorgen Sie das Gerät und die Batterien auf umweltfreundliche Art und Weise gemäß den Vorschriften Ihres Landes ES DESHACERSE DEL APARATO Reciclar el aparato y pilas usadas de forma ecologica conforme a las disposiciones legales de su pais PT COMO DESFAZER S...

Page 3: ...ture is 45 C Don t use this unit at higher ambient temperatures The electrical installation should be carried out by qualified personal only according to the regulations for electrical and mechanical safety in your country The cables should always be in perfect condition switch the LED Manager immediately off when the cables are squashed or damaged This appliance must be used with the LED Manager ...

Page 4: ...al waterproof junction boxes to make the junctions needed Another option is to open the waterproof metal enclosure 4 and to replace the original cable by your own cable In this case you can make the connection immediately inside the projector so you don t need a special waterproof junction box After checking that the maximum allowed power is not exceeded you can connect the cable coming from the p...

Page 5: ...ie de la classe de protection IP67 ainsi il peut être utilisé à l extérieur s il est correctement installé Les personnes non expérimentées ne doivent pas utiliser cet appareil La température ambiante maximum d utilisation de l appareil est de 45 C Ne pas l utiliser au delà de cette température Les installations électriques ne peuvent être faites que par du personnel qualifié et conformément aux ré...

Page 6: ...ode couleur nous vous recommandons d écrire les transitions de couleur entre les deux câbles ex blanc Æ noir bleu Æ bleu rouge vert Bleu blanc FRANÇAIS MODE D EMPLOI JB SYSTEMS 8 20 LED GROUND LIGHT vert Æ marron Ceci est extrêmement important sinon les projecteurs ne fonctionneront pas comme prévu Quand vous installez plusieurs projecteurs vous avez probablement besoin d une boîte de raccordement...

Page 7: ...vat Handleiding LED ground light VEILIGHEIDSVOORSCHRIFTEN Om het milieu te beschermen probeer zoveel mogelijk het verpakkingsmateriaal te recycleren Deze unit heeft beschermingsklasse IP67 daarom kan het buitenshuis worden gebruikt als het goed geïnstalleerd is Dit apparaat mag niet door onervaren personen bediend worden De maximum veilige omgevingstemperatuur is 45 C Gebruik het apparaat dus niet...

Page 8: ... 20 LED GROUND LIGHT Voor langere afstanden kan u de kabels verlengen met een normale elektrische installatiekabel van 4x1 5mm Wij wijzen u er op om als u geen kabel met dezelfde kleurcodes kan vinden de kleurovergangen tussen beide kabels op te schrijven bijvoorbeeld wit Æ black blauw Æ blauw groen Æ bruin Dit is extreem belangrijk anders zullen de projectors niet werken zoals verwacht U zal zeke...

Page 9: ...g bitte wiederverwenden oder richtig trennen Dieses Gerät entspricht der Schutzklasse IP67 und kann somit im Freien betrieben werden wenn es richtig installiert wurde Unerfahrene Personen sollen das Gerät nicht bedienen Umgebungstemperatur darf 45ºC nicht überschreiten Elektrische Anschlüsse nur durch qualifiziertes Fachpersonal überprüfen lassen Die Kabel sollten sich in gutem Zustand befinden Sc...

Page 10: ...identischer Farbkodierung finden können wird dringend empfohlen die Farbentsprechungen von beiden Kabeln notieren z B weiß Æschwarz blau Æ blau grün Æbraun usw Das ist sehr wichtig denn sonst funktioniert der Scheinwerfer nicht wie erwartet Wenn Sie mehrere Scheinwerfer installieren benötigen Sie spezielle wasserdichte Anschlusskästen um die benötigten Abzweigungen herzustellen ROTE GRÜN BLAU WEIS...

Page 11: ...e los siguientes ítems Instrucciones de manejo Luz de suelo LED INSTRUCCIONES DE SEGURIDAD Afín de evitar todo riesgo de incendio o electrocución no exponer el aparato a la lluvia o ambiente humedo Esta unidad tiene protección clase IP67 por lo que puede usarse en exteriores cuando se instale adecuadamente Personas sin experiencia no deberían manejar este aparato La temperatura máxima de ambiente ...

Page 12: ...ódigos de color recomendamos que anote las transiciones de color entre ambos cables ej blanco Æ negro azul Æ azul verde Æ marrón Esto es extremadamente importante o los proyectores no funcionarán como se desee Cuando instale múltiples proyectores necesitará cajas de acople impermeables especiales para realizar las uniones necesarias Rojo Verde Azul Blanco ESPAÑOL MANUAL DE INSTRUCCIONES JB SYSTEMS...

Reviews: