BEGLEC JB SYSTEMS LED GROUND LIGHT Operation Manual Download Page 3

ENGLISH  

OPERATION 

MANUAL 

 

 
JB SYSTEMS® 

1/20 

LED GROUND LIGHT 

 

 

 
Thank you for buying this JB Systems product. To take full advantage of all possibilities and for your own 
safety, please read these operating instructions very carefully before you start using this unit.  
 
 

FEATURES 

This unit is radio-interference suppressed. This product meets the requirements of the current European and 
national guidelines. Conformity has been established and the relevant statements and documents have been 
deposited by the manufacturer. 

  This device has been designed to produce decorative effect lighting and is used in light show systems. 

 Mechanically very strong multicolor RGB ground light, used for borders in parkways, entrances of 

discotheques, buildings, parkings, homes, etc. 

  Can also be used in al kinds of stone brick and concrete walls and ceilings. 

  To be used with the LED-MANAGER (dmx power supply) 

  39 very bright LEDs behind a thick milky translucent glass cover. 

  All-weather proof IP67 design with stainless steel cover ring. 

  Can be built-in any concrete (or other) floors, walls and ceilings. 

  Very easy electrical connection: 4-wire connection. 

 16cm overall diameter 

  Longlife LED Technology! 

  Power consumption = 3W only! 

 

BEFORE USE 

  Before you start using this unit, please check if there’s no transportation damage. Should there be any, do 

not use the device and consult your dealer first.  

 

Important: 

This device left our factory in perfect condition and well packaged. It is absolutely necessary 

for the user to strictly follow the safety instructions and warnings in this user manual. Any damage caused 
by mishandling is not subject to warranty. The dealer will not accept responsibility for any resulting defects 
or problems caused by disregarding this user manual. 

 Keep this booklet in a safe place for future consultation. If you sell the fixture, be sure to add this user 

manual. 

 

Check the contents: 

Check that the carton contains the following items: 

 Operating instructions 

  LED ground light unit 

 

SAFETY INSTRUCTIONS: 

  To protect the environment, please try to recycle the packing material as much as possible. 

  This unit has protection class IP67 so it can be used outdoors when it is properly installed. 

  Inexperienced persons should not operate this device. 

  Maximum save ambient temperature is 45°C. Don’t use this unit at higher ambient temperatures. 

 The electrical installation should be carried out by qualified personal only, according to the regulations for 

electrical and mechanical safety in your country. 

 The cables should always be in perfect condition: switch the LED Manager immediately off when the 

cables are squashed or damaged. 

 This appliance must be used with the LED Manager: don’t connect the unit to any dimmer pack or other 

power supply. 

  In the event of serious operating problems, stop using the fixture and contact your dealer immediately. 

  The housing and the lenses must be replaced if it is visibly damaged. 

  Please use the original packing when the device is to be transported. 

ENGLISH  

OPERATION 

MANUAL 

 

 
JB SYSTEMS® 

2/20 

LED GROUND LIGHT 

  Due to safety reasons it is prohibited to make unauthorized modifications to the unit. 

Important: 

Don’t use the effect in the presence of persons suffering from epilepsy. 

 
 

DESCRIPTION: 

 

1.  Strong stainless ring with 3 bolts used to keep the glass cover safely in place. 
2.  Strong glass cover with rubber sealing to ensure the enclosure is waterproof. 
3.  3 screws used to fix the waterproof metal body inside the plastic niche mounting box. 
4.  Waterproof metal enclosure with LED lights inside. 
5.  Plastic niche mounting box used to install the projector in the floor (or wall/ceiling) 
6.  4 special “press on” wire connections.  
 
 

MECHANICAL INSTALLATION 

 

Important:

 

The installation must be carried out by qualified service personal only. Improper 

installation can result in serious injuries and/or damage to property. Certified installation materials 
should be used, the installed device should be inspected regularly for safety.

 

  Make sure the area around the installation place is free from unwanted persons during installation and 

servicing. 

 Separate  the  plastic  niche 

mounting box (5) from the rest of 
the projector. 

 First install the mounting box at 

the right spot in the floor. See the 
drawing for more information. 

 

Close the projector after 
connecting the electrical wires 
(see next chapter) 

 Make sure the wire inlet on the 

waterproof metal housing is well 
fastened and sealed so that no 
water can come in. 

  Fix the metal enclosure to the niche mounting box using the 3 screws. 

  Make sure the collar on the upper side of the metal housing is free from dirt or dust. 

  Make sure the glass cover and its rubber sealing are clean and put them in place. 

  Install the stainless metal ring and fasten with the 3 special bolts.  

Summary of Contents for JB SYSTEMS LED GROUND LIGHT

Page 1: ...ontent in any manner without express permission of the publisher is prohibited LED GROUND LIGHT LED GROUND LIGHT LED RGB PASSIVE GROUND LIGHT P6 I 7 ROO WATERP F Version 1 1 Operation Manual Mode d emploi Gebruiksaanwijzing Bedienungsanleitung Manual de instrucciones EN FR NL DU ES ...

Page 2: ...t toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften DU ENTSORGUNG DES GERÄTS Entsorgen Sie das Gerät und die Batterien auf umweltfreundliche Art und Weise gemäß den Vorschriften Ihres Landes ES DESHACERSE DEL APARATO Reciclar el aparato y pilas usadas de forma ecologica conforme a las disposiciones legales de su pais PT COMO DESFAZER S...

Page 3: ...ture is 45 C Don t use this unit at higher ambient temperatures The electrical installation should be carried out by qualified personal only according to the regulations for electrical and mechanical safety in your country The cables should always be in perfect condition switch the LED Manager immediately off when the cables are squashed or damaged This appliance must be used with the LED Manager ...

Page 4: ...al waterproof junction boxes to make the junctions needed Another option is to open the waterproof metal enclosure 4 and to replace the original cable by your own cable In this case you can make the connection immediately inside the projector so you don t need a special waterproof junction box After checking that the maximum allowed power is not exceeded you can connect the cable coming from the p...

Page 5: ...ie de la classe de protection IP67 ainsi il peut être utilisé à l extérieur s il est correctement installé Les personnes non expérimentées ne doivent pas utiliser cet appareil La température ambiante maximum d utilisation de l appareil est de 45 C Ne pas l utiliser au delà de cette température Les installations électriques ne peuvent être faites que par du personnel qualifié et conformément aux ré...

Page 6: ...ode couleur nous vous recommandons d écrire les transitions de couleur entre les deux câbles ex blanc Æ noir bleu Æ bleu rouge vert Bleu blanc FRANÇAIS MODE D EMPLOI JB SYSTEMS 8 20 LED GROUND LIGHT vert Æ marron Ceci est extrêmement important sinon les projecteurs ne fonctionneront pas comme prévu Quand vous installez plusieurs projecteurs vous avez probablement besoin d une boîte de raccordement...

Page 7: ...vat Handleiding LED ground light VEILIGHEIDSVOORSCHRIFTEN Om het milieu te beschermen probeer zoveel mogelijk het verpakkingsmateriaal te recycleren Deze unit heeft beschermingsklasse IP67 daarom kan het buitenshuis worden gebruikt als het goed geïnstalleerd is Dit apparaat mag niet door onervaren personen bediend worden De maximum veilige omgevingstemperatuur is 45 C Gebruik het apparaat dus niet...

Page 8: ... 20 LED GROUND LIGHT Voor langere afstanden kan u de kabels verlengen met een normale elektrische installatiekabel van 4x1 5mm Wij wijzen u er op om als u geen kabel met dezelfde kleurcodes kan vinden de kleurovergangen tussen beide kabels op te schrijven bijvoorbeeld wit Æ black blauw Æ blauw groen Æ bruin Dit is extreem belangrijk anders zullen de projectors niet werken zoals verwacht U zal zeke...

Page 9: ...g bitte wiederverwenden oder richtig trennen Dieses Gerät entspricht der Schutzklasse IP67 und kann somit im Freien betrieben werden wenn es richtig installiert wurde Unerfahrene Personen sollen das Gerät nicht bedienen Umgebungstemperatur darf 45ºC nicht überschreiten Elektrische Anschlüsse nur durch qualifiziertes Fachpersonal überprüfen lassen Die Kabel sollten sich in gutem Zustand befinden Sc...

Page 10: ...identischer Farbkodierung finden können wird dringend empfohlen die Farbentsprechungen von beiden Kabeln notieren z B weiß Æschwarz blau Æ blau grün Æbraun usw Das ist sehr wichtig denn sonst funktioniert der Scheinwerfer nicht wie erwartet Wenn Sie mehrere Scheinwerfer installieren benötigen Sie spezielle wasserdichte Anschlusskästen um die benötigten Abzweigungen herzustellen ROTE GRÜN BLAU WEIS...

Page 11: ...e los siguientes ítems Instrucciones de manejo Luz de suelo LED INSTRUCCIONES DE SEGURIDAD Afín de evitar todo riesgo de incendio o electrocución no exponer el aparato a la lluvia o ambiente humedo Esta unidad tiene protección clase IP67 por lo que puede usarse en exteriores cuando se instale adecuadamente Personas sin experiencia no deberían manejar este aparato La temperatura máxima de ambiente ...

Page 12: ...ódigos de color recomendamos que anote las transiciones de color entre ambos cables ej blanco Æ negro azul Æ azul verde Æ marrón Esto es extremadamente importante o los proyectores no funcionarán como se desee Cuando instale múltiples proyectores necesitará cajas de acople impermeables especiales para realizar las uniones necesarias Rojo Verde Azul Blanco ESPAÑOL MANUAL DE INSTRUCCIONES JB SYSTEMS...

Reviews: