16
Start Engine
Notice
If your engine is starting, do an inspection on
the top cooling fan, and ensure it is operating.
Otherwise, you should stop the engine.
If the engine starts but does not run, make certain that the generator is on a flat, level surface. The
engine is equipped with a low oil sensor that will prevent the engine from running when the oil level
falls below a critical threshold.
Notice
1.
This generator must have at least 5 feet (about 1.5 meters) of clearance from combustible material.
2.
Leave at least 3 feet (about 1 meter) of clearance on all side of the generator to allow for adequate
cooling, maintenance and servicing.
3.
Place the generator in a well-ventilated area.
4.
DO NOT place the generator near vents or intakes.
Caution
!
!
!
Step 1: Open gas fuel source (NG or LPG).
Step 2: Turn engine switch at ON position.
Step 3: Push electric start push button to
start engine. If the engine fails to start
with 5 seconds, release the button and
wait at least 5 seconds before attempting
to start engine again.
Step 4: Turn circuit breaker at ON position.