Type
BMG5
Flow rate
QLPG
≥
2.0 kg/h
or QLPG
≥
1 m
3
/h
Regulator outlet pressure
2.8
±
0.5KPa
(0.4
±
0.07 PSI)
14
1.
LPG Pressure Regulator should be equipped on LPG cylinder.
2.
Be sure place the LPG cylinder vertically.
Regulator outlet pressure should be as follow:
Working Condition
Environment Requirement
Gas Requirement
Temperature:
for NG powered generator set: -30
℃
~
40
℃
;
for LPG powered generator set: -5
℃
~
40
℃
.
Sea level:
Height above sea level: below 1000m
The generator output power will decline if working above sea level 1000m.
LPG
Main Gas Valve should be equipped on main gas pipe.
Recommended gas pressure: 2.0
~
6.0kPa ( 0.29
~
0.87 PSI)
Natural Gas
NG
Gas switch (main gas valve)
Gas pressure regulator
Summary of Contents for BMG5