25
EN
Keep-Warm Function
The device has an automatic keep-warm function which can be switched on or off as you wish
before starting the brewing process.
Switching on the hotplate –
Press the
ON
/
OFF
button (
13
) just brie
fl
y to start the brewing
process. The operating lamp (
11
) lights up red and the hotplate (6) remains switched on for
approx. 40 minutes.
Switching off the hotplate –
Press the
ON
/
OFF
button for at least 2 seconds to start the
brewing process. The operating lamp
fl
ashes and the hotplate switches off once the brewing
process has ended.
PLEASE NOTE:
The keep-warm function can also be switched on or off when brewing coffee
with a preset time. As the preset time is activated with the
AUTO
button (
16
), this button must
then be pressed either for a brief time or for at least 2 seconds.
We recommend always switching off the keep-warm function when using the device with a
thermal jug.
Drip Stop
The device has a drip stop (
4
) which prevents water from dripping out of the
fi
lter compartment
when the jug has been removed from the device (
Picture
B
).
When the device is in operation, the
fi
lter compartment (
3
) must be closed and a jug with a lid
placed on it must be placed beneath the
fi
lter compartment. The lid of the jug pushes the drip
stop upwards and the coffee can
fl
ow from the
fi
lter through the lid into the jug.
During the brewing process, the jug
must not be removed from the device for longer than
30 seconds
as otherwise the
fi
lter could over
fl
ow.
Preparation
PLEASE NOTE
•
Do not operate the device without water or with less water than is required to reach the
MIN
mark (approx. 250 ml). If this does happen, the device switches off automatically. In this
case, allow the device to cool down before water is poured in and the device is used again.
•
Never
start a brewing process without a jug with a closed lid beneath the coffee outlet.
1. Fill the water tank (
9
) with water (see the “Handling and Operation” chapter | “Filling the
Water Tank”).
2. Insert the permanent
fi
lter (
2
) into the
fi
lter compartment (
3
) (see the “Handling and
Operation” chapter | “Inserting the Permanent Filter”).
3. Pour the amount of ground coffee you want into the permanent
fi
lter using a suitable spoon.
We recommend one level coffee measuring spoon per 125 ml.
4. Place the glass jug (
5
) or the thermal jug under the coffee outlet (
4
).
Summary of Contents for 05958
Page 44: ...FR 46...