Once you have placed the Beefer in a location that satisfies the above-mentioned safety instructions, you can start
connecting it with the gas cylinder.
The gas cylinder must be placed in an upright stable position at a distance from the Beefer without overstretching
the tube and without touching parts of the Beefer at any point. But at the same time it should be so far away so
that heat radiation from the Beefers does not reach the surface of the gas cylinder or the gas tube.
Now you must connect the pressure regulator to the gas cylinder’s valve.
Note that the screw joints are of left-handed thread.
Use a suitable tool and do not use the pressure regulator for tightening the screw joint with the gas cylinder.
ATTENTION:
If the tube has a maximum prescribed period of use, if the local regulations require it and/or it is expired or
shows porous or damaged areas, replace it. If you smell gas during the Beefer’s operation or suspect any leakage
of gas-bearing components, you must cut off the gas supply immediately. You may start the Beefer again only after
rectifying the cause of leakage.
Precautions:
-
LP gas is highly flammable and highly explosive.
-
Too high concentration of gas can cause suffocation from lack of oxygen.
-
LP gas is heavier than oxygen and may lead to harmful gas concentrations at the bottom of sinks or, for
example, in small poorly ventilated courtyards in case of uncontrolled outflow.
-
Make sure that there is no uncontrolled outflow of the LP gas.
-
When you are using the gas cylinders, follow the requirements of the manufacturer or those of its lender.
-
Use the Beefer exclusively outdoors and always make sure of adequate ventilation.
-
Make sure that the gas tube does not come into contact with the Beefer.
-
The gas cylinder and the tube may not be exposed to temperatures exceeding 50°C. (122°F)
-
When you are connecting the gas cylinder there should not any source of ignition in the vicinity of the
Beefer, especially no open flames or burning cigarettes, candles, lamps and so on. Even electrical equipment
can pose a danger, if the gas escapes when connecting it.
-
Do not use the Beefer if the gas tube is porous or defective.
-
Before each use, make sure to check the gas tubes and connections. And after a long gap,
check the burner area and venturi tube for traces of foreign bodies, such as insects, which could clog the gas
supply. Remove them carefully with suitable instruments
Connecting the gas cylinder :
4
Summary of Contents for Beefer 1
Page 1: ...D english Englisch ingl s...