12
Outdoor Installation Instructions
Warning: Contact your local municipality for any building codes regulating the installation of outdoor
barbecue appliances. Outdoor installations must conform to local codes or, in the absence of local
codes, with the following.
USA:
National Fuel Gas Code, ANSI Z223.1/NFPA 54
CAN:
B149.1 Natural Gas & Propane Installation Code
Aust
:
Australian Standards Code AS:5601/AG601
•
When using an LPG supply system in an enclosure, ventilation must be provided. Gas vapour is
highly explosive and can cause serious bodily injury or damage to property if allowed to accumulate
in a confined space and ignited.
• We recommend that this installation be done in a masonry structure and carried out by a
professional tradesperson. Other non-combustible material such as compressed fibro cement
sheeting with metal studs may also be used.
• This appliance must not be installed under or on any combustible material. Minimum clearance from
combustible construction materials to all sides of the appliance is 450mm (18”).
• These specifications must be left with the owner.
Model
MM
INCHES
2 Burner 523mm
20.59"
3 Burner 690mm
27.16"
4 Burner 846mm
33.30"
5 Burner 1003mm
39.48"
Propane (LPG) installation
Approved
Propane regulator
(not included)
Propane / LPG
Cylinder
(not included)
Natural gas Installation
Approved
Natural Gas regulator
Shut off valve
(not included)
Stainless steel flex line or AGA
approved hose (not included)
Typical installation drawing
200mm min
510mm min / 20.07"
Dimension "X"
450mm / 18" minimum
rear clearance to
any combustible
material
1
2
Optional Build-in
brackets