9
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
LPG/Propane Cylinder
If your barbecue is to be connected to a portable LPG
cylinder, you should position it in the far right drawer� Place
the prefitted mat down first, then position the cylinder on
top� Secure the cylinder by wrapping the strap around the
cylinder and clipping it to the bracket slots as shown in the
illustration�
Partial Enclosures (Australia Only)
This appliance shall only be used in an above ground, open
air situation with natural ventilation, without stagnant areas,
where gas leakage and products of combustion are rapidly
dispersed by wind and natural convection� Any enclosure
in which the appliance is used shall comply with one of the
following:
Within a partial enclosure that includes an
overhead cover and no more than two walls�
A common example is an outdoor gazebo�
Any enclosure with walls on all sides, but at
least one permanent opening at ground level,
and no overhead cover�
A common example is an enclosed back yard�
Typically, the walls are less than 3m high�
If they are higher, there is a danger of gas
build up�
The barbecue may be within a partial
enclosure that includes an overhead
cover and more than two walls, the
following shall apply:
•
At least 25% of the total wall area
is completely open; and
•
at least 30% of the remaining wall
area is open and unrestricted�
In the case of balconies, at least 20% of
the total of the side, back and front wall
areas shall be and remain open and
unrestricted�