10
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
Before You Begin
Check that the gas type is correct for your type of gas
�
You will find the gas type label on the side of your barbecue�
If your barbecue is of the incorrect gas type, or if you are
unsure, consult your dealer before going any further�
This appliance must have a minimum clearance from
combustible materials of 450 mm (18”) on all sides of the
barbecue�
Do not install the appliance under or on any combustible
surface�
The appliance must be tested for safe and proper operation
on completion of installation�
Keep ventilation openings in the lower cabinet clear and
free of any debris� This barbecue is not approved for use on
marine craft�
For POL cylinders, tighten
anti-clockwise
For Quick Connect
cylinders, tighten clockwise
NATURAL
GAS
R
E
FE
R
TO
LO
C
A
L
GAS AUTHORITY FOR CONFIRMATION OF GAS
U
O
D
NI
FI
EP
YT
T
B
LPG
PROPANE
GAS
R
E
FE
R
TO
LO
C
A
L
GAS AUTHORITY FOR CONFIRMATION OF GAS
YT
P
FI
E
T
B
U
O
D
NI
Mobile Installation - Portable LP Gas/ Propane
Recommended minimum LPG/propane cylinder capacity
for use with this appliance is 4kg� Maximum LPG/propane
cylinder capacity for use with this appliance is 10kg� In the
USA, only a 20lb cylinder may be used�
Fit the regulator to the LPG/propane cylinder, as shown on
the right� Secure all joints spanner (wrench) tight but do not
over-tighten�
For POL cylinders, tighten anti-clockwise
For Quick Connect cylinders, tighten clockwise
Fixed Installation - Portable LP Gas/Propane.
BeefEater LPG/propane barbecues are designed to operate
at 2�75Kpa (11”WC)�
Connect the gas supply line to the barbecue inlet located on
the right side of the appliance using either hard plumbing,
or a flexible hose connected to a bayonet point, also known
as a quick connect fitting� Refer to AS 5601 or your local
installation code for pipe sizing details� Secure all joints
spanner (wrench) tight but do not over-tighten�
Test gas pressure by removing the last burner from the
left hand side of the barbecue and attaching a hose and
pressure gauge to the end of the gas valve� Turn on 2
burners and check the pressure� Inlet pressure should be
11�0” WC or 2�75 kPa�
Australia only: For mobile trolley installations that use
flexible hosing to connect to natural gas, a chain or similar
restraining device must be fitted to prevent strain on the
gas supply line� One end of the chain should attach to the
barbecue; the other end should attach to a fixed structural
point close to where the hose connects to the gas piping�
The chain must be at least 30% shorter than the gas supply
line� In this way, if the barbecue is accidentally moved, the
chain stops the barbecue from stretching the hose�
Fixed Installation - Natural Gas
(Natural Gas installation should be carried out by a qualified
gas fitter)�
BeefEater Natural Gas barbecues are designed as low-
pressure appliances (4�0” WC, 1�00KPa)�
Fit the natural gas regulator supplied directly to the
barbecue inlet located on the right side of the appliance
using either hard plumbing, or a flexible hose connected to
a bayonet point, also known as a quick connect fitting� Refer
to AS 5601 or your local installation code for pipe sizing
details� Secure all joints spanner (wrench) tight but do not
over-tighten�
Test gas pressure by removing the last burner from the
left hand side of the barbecue and attaching a hose and
pressure gauge to the end of the gas valve� Turn on 2
burners and check the pressure� Inlet pressure should be
4�0” WC or 1�00 kPa�
Australia only: For mobile trolley installations that use
flexible hosing to connect to natural gas, a chain or similar
restraining device must be fitted to prevent strain on the
gas supply line� One end of the chain should attach to the
barbecue; the other end should attach to a fixed structural
point close to where the hose connects to the gas piping�
The chain must be at least 30% shorter than the gas supply
line� In this way, if the barbecue is accidentally moved, the
chain stops the barbecue from stretching the hose�
The barbecue appliance must be isolated from the gas
supply piping system by closing its manual shutoff valve
during any pressure testing of the gas supply piping system�
Summary of Contents for 1200E
Page 22: ...22 NOTES NOTE ...