11. BEDFORD-B800-200V series standard size
BEDFORD- B800
2001
2002
2003
2005
2007
2010
Voltage 1or
3
φ
200V-240V 3
φ
200V-240V
Capacity (KW)
0.75
1.5 2.2 3.7 5.5 7.5
Rated output voltage (V)
3
φ
220V-240V
Rated output current A
4.3
7.0
10.5
14
19.6
26.6
Control mode
Sine wave PWM control
Output frequency range
Maximum 545Hz
Frequency resolution
Analog input volume: 0.1Hz
Overloading capacity
Rated output 150%-1 minute; 175% -2 seconds.
Frequency setting signal
0~10V
,
10~0V
,
-10~10V
,
4~20mA
,
0~20mA
,
20~4mA
6 types of standard signals.
No. of V/F Patterns
Random V/F curve.
Location
Indoor (protected from corrosive gases and dust)
Ambient temperature
-10~40
℃
(if beyond the allowable degree, one
degree will derogate 5% of output current).
Storage temperature
-40~60
℃
Environmental temperature
95%
(
without dew gather
)
Vibration 2M/S
2
(
0.2G
)
Protection rate
IP20
B800-200-05/0.5HP/0.37KW is available
B800-200-07/0.7HP/0.55KW is available