F-33 DC injection braking on enable
When F-33 to “1”, DC injection is applied whenever the drive is enabled
•
F-34 External brake resistor
Activate interior brake resistor.
When F-42=1, Brake resistor functions enable.
When F-42=2, Overload protection is required to avoid damages of both
resistor and drive
•
F-35 Speed reference scaling factor
Scales the analog input at control terminal 6 up or down, or the digital
reference in keypad (or Slave) mode up or down (see F-12)
•
F-36 Communication address(Drive address).
0 means order invalid
•
F-37 Access code definition
Defines Extended Parameter Set access code F-14
•
F-38 Parameter access lock
Controls user access to parameters.
When F-38=0, all parameters can be changed and these changes will
be stored automatically.
When F-38=1, changes may be made, but these will not be stored when
the drive power cut off.
When P-38=2, Parameters are locked and cannot be changed thus
preventing unauthorized access