5 Programming

5.1 Procedure

For the programming of the EMS-8x, the device has to be opened. At the control board inside of
the ISO box there are three buttons available.
By pressing the ”P” button you will enter the programming mode which is indicated in the display
by “Pro”. This state can be left by pushing the “+” button. During runtime an emergency stop can
be performed by pushing the “-” button. An emergency stop will reset the device to “free” state
By pressing the ”P” button another time you are in the parameter edit mode. The display shows
alternating a ”P”, followed by the parameter number and the value of the respective parameter.
Press the ”P” button several times until you reach the required parameter. You can find a listing of
all parameters in Table 1, section 5.5. By pressing the „P“ button another time if the last paramter is
reached, all settings are stored and the EMS-8x is in “free” state again. All parameters are stored
electronically and do not loose their values even if the device is switched off. If no button is
pressed for a period of at least 30 seconds, all settings are stored automatically and the EMS-8x
changes over to “free” state. In the following sections the 3 types of parameters, counter, operating
values and switches, are described.

5.2 Counter editing

Counters   are  cash  counters,   customer   counters   or   hour   meters.  There   are  erasable   and   non-
eraseable counters. The erasable counters can be erased by pressing the ”+” or ”-”button.

Some counters have a range higher than 999. As the display has only 3-digits, the notation is
segmented on values higher than 999. The display changes between the parameter-number, the
high level digits (digits 4 - 5) and the low level digits (digits 1 - 3). The high level digits are
indicated by the flashing decimal point at the right side. In Figure 4 you can see an example for the
counter operating hours 1 with a counter value of 21 740 hours. If the value is lower than 1.000 the
display changes only between the parameter number and the low level digit display.

5.3 Adjusting operating parameters

Operating parameters are values, you can adjust the prices or the maximum time with. These
values can be increased by pressing the button ”+” and decreased by pressing the button ”-”. The
rate is either 1 or 0,1 depending on the parameter. On pressing the ”+” resp. ”-” button for a longer
time, the value can be changed faster.

5.4 Switch-parameter

By means of the switches a function can be switched on or off. These parameters have
two options only, which can be changed by pressing the ”+” or ”-” button.

Page 11

Figure 6:

 Counter display for larger values

Summary of Contents for EMS-8 Series

Page 1: ...Coin box EMS 8x EMS 8x TE User manual Basic version and version with door unlocking Beckmann GmbH 2015 07 05 2015 ...

Page 2: ...caused by the buyer or other persons by accident misuse unauthorized changes repair or innovations of the product Furthermore the Beckmann GmbH is not liable for losses costs faults or consequential losses that may emerge by using this product The technical data correspond to the current conditions Misprints errors or changes reserved Beckmann GmbH Brandtstraße 1 33161 Hövelhof Fon 49 0 52 57 98 2...

Page 3: ... 14 6 1 Switching on 14 6 2 Factory default settings 14 6 3 Software version 14 6 4 Readout serial number 14 7 Electronic coin validator only EMS 82 15 8 Software update with SD card adapter 16 9 Technical data 17 10 EC Declaration of Conformity 18 List of figures Figure 1 Dimensions 5 Figure 2 Connection diagram Regular version with Output 6 Figure 3 Connection diagram version Potential free 7 Fi...

Page 4: ...tless conditions as well as due safety and risk conscious regarding the user manual Especially eliminate faults that may impair safety immediately Keep the user manual always on site of the device Pay attention additional to the user manual to the general valid legal and other obligatory rules such as accident prevention and environmental protection Do not make any changes and or modifications wit...

Page 5: ...bly in rooms For fixing the device there are three drillings with a diameter of 6 mm at the back side It must be taken care that the case is mounted vertically because otherwise the functioning of the coin selector may be reduced The EMS 8x should be mounted at a solid wall in order to avoid heavy vibrations Page 5 Figure 1 Dimensions ...

Page 6: ...ain electrical systems to wire switch and control cabinets to install controlling software to ensure proper functioning of electrical components and to identify possible hazards in the work with electric and electronic systems Since this is a stationary device with a fixed main power supply an RCBO must be installed on the installation side Requirements main power supply is power less RCBO is swit...

Page 7: ...User Manual EMS 8x EMS 8x TE Beckmann GmbH Page 7 Figure 3 Connection diagram version Potential free ...

Page 8: ...he stripped wire through the round clamp opening into the opened spring cage 3 Remove the screwdriver 4 Check the fixed position of the conductor by gently pulling the cable CAUTION Do not push the wire into the square clamp opening Do not push the wire into the clamp before clamp is fully opened refer to sequence above Otherwise the contact is not sufficient and it may create sparks or fires Defe...

Page 9: ...ual EMS 8x EMS 8x TE Beckmann GmbH 3 3 Maintenance The devices of the EMS 8x series are nearly maintenance free Only the coin selector has to be cleaned sometimes in order to guarantee a proper operation Page 9 ...

Page 10: ... time has run out completely the display shows 0 and the output shuts off 4 2 Door opener EMS 8x TE This feature is mainly provided for washing machines and dryers As some washing machines or dryers need power in order to open the door the EMS 8x TE owns a push button at the front that can be used for switching the output for a moment The duration can be determined by parameter P36 within the prog...

Page 11: ...ing sections the 3 types of parameters counter operating values and switches are described 5 2 Counter editing Counters are cash counters customer counters or hour meters There are erasable and non eraseable counters The erasable counters can be erased by pressing the or button Some counters have a range higher than 999 As the display has only 3 digits the notation is segmented on values higher th...

Page 12: ...P05 Counter 0 to 49 999 P10 Operating Hours 1 Operation Hours in hours and minutes Counter 0 to 99 999 59 P11 Operating Hours 2 not erasable as P10 Counter 0 to 99 999 59 P20 EMS 81 Minimum Insertion Indicates the amount of coins that has to be inserted at least Operat 1 to 100 EMS 82 Minimum Insertion Indicates the amount of money that has to be inserted at least Operat 0 01 to 599 99 P21 Time re...

Page 13: ...ce is free after a power failure Switch On Off P33 Show Amount instead of Time If ON the remaining amount of money is displayed instead of the remaining time Switch On Off P35 only TE Number of door opening Determines how often the door opener may be used before the blocking time starts Operat 1 to 99 P36 only TE Time of door opening Determines the duration of the door opener feature in minutes an...

Page 14: ...ttings appears in the display 6 3 Software version With parameter P99 details about the software version can be read out Press to switch between the subparameters P99 1 to P99 6 P99 1 Software version P99 2 Language coin table 1 German 2 English 3 German_Switzerland 4 Denmark 5 Latvia 6 Norway 7 Czechia P99 3 Feature 1 P99 4 Feature 2 P99 5 Feature 3 P99 6 Feature 4 6 4 Readout serial number For s...

Page 15: ...mal tolerance ranges This is the default factory setting Strict Validation Coins are analyzed in strict tolerance ranges Improved detection of counterfeits The acceptance of the set coin type has been slightly decreasing The lock switch normal must be set to ON Very strict Validation Coins are analyzed in very strict tolerance ranges Improved detection of counterfeit coins The acceptance of the co...

Page 16: ...n of the circuit board must be identified In version 1 v1 the red socket is located on the left side Please use plug no 1 In version 2 v2 the red socket is located below the three push buttons Please use plug no 2 To start the update the device must be switched on Please wait until the process is complete Page 16 Figure 7 SD card adapter with numbered connectors Figure 8 Identification hardware ve...

Page 17: ...ta Typ 230V Typ 24V Power source 230V AC 50Hz 24V AC Power consumption 5W Max switched power max 16A Operating temperature 0 to 40 C Operating humidity 30 to 70 Weight 3 5kg Dimensions B x H x T 162 x 260 x 110 mm Data retention in off state 20 years Page 17 ...

Page 18: ...User Manual EMS 8x EMS 8x TE Beckmann GmbH 10 EC Declaration of Conformity Page 18 ...

Page 19: ...User Manual EMS 8x EMS 8x TE Beckmann GmbH Page 19 ...

Page 20: ...User Manual EMS 8x EMS 8x TE Beckmann GmbH Page 20 ...

Reviews: