Data structures of the modules
KL85xx und KL9309
83
Version: 2.1.0
Process data
Input data (DataIN1 to DataIN8)
Position of the potentiometers with user scaling switched off (
Potentiometer
position
Input value in the PLC
hexadecimal
decimal
CCW stop
0x0000
0
Center
0x3FFF
16383
CW stop
0x7FFF
32767
Output data (DataOUT1 to DataOUT8)
Specification of the output values by the controller.
Output value
Output voltage
hexadecimal
decimal
0x0000
0
0 V
0x3FFF
16383
+5 V
0x7FFF
32767
+10 V
5.4.2
KL8548 - control and status bytes
Channel 1
Process data mode
Control byte 1 in process data mode
Control byte 1 (CB1) is located in the
, and is transmitted from the controller to the
terminal.
Bit
CB1.7
CB1.6
CB1.5
CB1.4
CB1.3
CB1.2
CB1.1
CB1.0
Name
RegAccess -
-
-
-
-
-
-
Key
Bit
Name
Description
CB1.7
RegAccess
0
bin
Register communication off (process data mode)
CB1.6 - CB1.0
-
0
bin
reserved
Status byte 1 in process data mode
The status byte 1 (SB1) is located in the
and is transmitted from terminal to the controller.
Bit
SB1.7
SB1.6
SB1.5
SB1.4
SB1.3
SB1.2
SB1.1
SB1.0
Name
RegAccess -
-
-
-
-
-
auto/man