Comissioning and Configuration
EP9214-0023 and EP9224-0023
51
Version: 2.3.1
4.5.1.1.3
Index 8010 DPO Settings Ch.2
Index
Name
Meaning
Data type
Flags
Default
8010:0
DPO Settings
Ch.2
UINT8
RO
0x13 (19
dec
)
8010:02
Default State Us The output adopts this value if F707:01 is not set
boolean
RW
0x01 (1
dec
)
8010:03
Default State Up The output adopts this value if F707:01 is not set
boolean
RW
0x01 (1
dec
)
8010:11
Characteristic
Specifies the characteristic with which the current monitor-
ing reacts:
0
dec
: very fast acting
1
dec
: fast acting
2
dec
: slow acting
3
dec
: time delay
UINT16
RW
0x0001 (1
dec
)
8010:12
Nominal Current
Us
Nominal maximum current at the output
UINT16
RW
0x0FA0 (4000
dec
)
8010:13
Nominal Current
Up
Nominal maximum current at the output
UINT16
RW
0x0FA0 (4000
dec
)
4.5.1.1.4
Index 8020 DPO Settings Ch.3
Index
Name
Meaning
Data type
Flags
Default
8020:0
DPO Settings
Ch.3
UINT8
RO
0x13 (19
dec
)
8020:02
Default State Us The output adopts this value if F707:01 is not set
boolean
RW
0x01 (1
dec
)
8020:03
Default State Up The output adopts this value if F707:01 is not set
boolean
RW
0x01 (1
dec
)
8020:11
Characteristic
Specifies the characteristic with which the current monitor-
ing reacts:
0
dec
: very fast acting
1
dec
: fast acting
2
dec
: slow acting
3
dec
: time delay
UINT16
RW
0x0001 (1
dec
)
8020:12
Nominal Current
Us
Nominal maximum current at the output
UINT16
RW
0x0FA0 (4000
dec
)
8020:13
Nominal Current
Up
Nominal maximum current at the output
UINT16
RW
0x0FA0 (4000
dec
)
4.5.1.1.5
Index 8030 DPO Settings Ch.4
Index
Name
Meaning
Data type
Flags
Default
8030:0
DPO Settings
Ch.4
UINT8
RO
0x13 (19
dec
)
8030:02
Default State Us The output adopts this value if F707:01 is not set
boolean
RW
0x01 (1
dec
)
8030:03
Default State Up The output adopts this value if F707:01 is not set
boolean
RW
0x01 (1
dec
)
8030:11
Characteristic
Specifies the characteristic with which the current monitor-
ing reacts:
0
dec
: very fast acting
1
dec
: fast acting
2
dec
: slow acting
3
dec
: time delay
UINT16
RW
0x0001 (1
dec
)
8030:12
Nominal Current
Us
Nominal maximum current at the output
UINT16
RW
0x0FA0 (4000
dec
)
8030:13
Nominal Current
Up
Nominal maximum current at the output
UINT16
RW
0x0FA0 (4000
dec
)
4.5.1.1.6
Index F707 DPO Outputs Device
Index
Name
Meaning
Data type
Flags
Default
F707:0
DPO Outputs
Device
UINT8
RO
0x04 (4
dec
)
F707:01
Enable Control
Via Fieldbus
0
bin
: All outputs are set to their default values (80X0:02,
80X0:03)
1
bin
: All outputs are set according to their PDOs (70X0:01,
70X0:02)
boolean
RO
0x00 (0
dec
)
F707:04
Global Reset
All error bits are reset
boolean
RO
0x00 (0
dec
)