![Beckhoff ELX3312 Operating Manual Download Page 14](http://html1.mh-extra.com/html/beckhoff/elx3312/elx3312_operating-manual_2719618014.webp)
Product overview
ELX3312 and ELX3314
14
Version: 1.3.0
2.3
Technical data
Technical data
ELX3312-0000
ELX3314-0000
Technology
temperature measurement
Sensor types
thermocouples type B, C, E, J, K, L, N, R, S, T, U
(default: Type K)
Number of inputs
2 (differential)
4 (differential)
Connection method
2-wire
2-wire
Measuring range (depending on sensor
type):
type B: +200 ... +1820°C
type C: 0 ... +2320°C
type E: -270 ... +1000°C
type J: -210 ... +1200°C
type K: -270 ... +1370°C (default)
type L: -50 ... +900°C
type N: -270 … +1300°C
type R: -50 ... +1750°C
type S: -50 ... +1750°C
type T: -270 … +400°C
type U: -50 … +600°C
voltage measurement: ±30…±75 mV
Resolution
0.1°C per digit
Measuring error
< ±0.3 % (relative to full scale value)
Internal resistance
≥ 10 kΩ typ. (differential)
Input filter limit frequency
typical 1 kHz, depending on sensor length, conversion time,
sensor type
Conversion time
adjustable: 50…5000 ms
(default: 270 ms)
adjustable: 50…5000 ms
(default: 310 ms)
Supply voltage electronics
via E-Bus (5 V
DC
) and Power Contacts (24 V
DC
Ex, feeding by
ELX9560)
Current consumption from the E-Bus
typically 70 mA
Current consumption from Power Contacts typically 10 mA + load (ELX9560 power supply)
Special features
limit value monitoring, digital filter and characteristic curve
linearization integrated
Bit width in the process image
2 x 32 bit input
4 x 32 bit input
Electrical isolation
1500 V (E-Bus / field voltage)
Weight
app. 60 g
Permissible ambient temperature range
during operation
-25°C ... + 60°C
Permissible ambient temperature range
during storage
-40°C ... + 85°C
Permissible relative humidity
95%, no condensation
Permissible air pressure
(operation, storage, transport)
800 hPa to 1100 hPa
(this corresponds to a height of approx. -690 m to 2000 m over
sea level assuming an international standard atmosphere)
Dimensions (W x H x D)
app. 15 mm x 100 mm x 70 mm (width aligned: 12 mm)
on 35 mm mounting rail conforms to EN 60715
Vibration / shock resistance
conforms to EN 60068-2-6 / EN 60068-2-27
EMC immunity / emission
conforms to EN 61000-6-2 / EN 61000-6-4
Protect. class
IP20
Permissible installation position
See chapter
Installation position and minimum distances
Approvals / markings
CE, UL, ATEX, IECEx, cFMus