Commissioning
EL6201
187
Version: 2.2
Index 1A40 ASI TxPDO-Map Inputs Device
Index (hex) Name
Meaning
Data type
Flags
Default
1A40:50
SubIndex 080
80. PDO Mapping entry (object 0xF600 (ASI Digital In-
puts), entry 0x50 (Slave 10 Inputs__Slave 10B, DI3))
UINT32
RO
0xF600:50, 1
1A40:51
SubIndex 081
81. PDO Mapping entry (object 0xF600 (ASI Digital In-
puts), entry 0x51 (Slave 11 Inputs__Slave 11A, DI0))
UINT32
RO
0xF600:51, 1
1A40:52
SubIndex 082
82. PDO Mapping entry (object 0xF600 (ASI Digital In-
puts), entry 0x52 (Slave 11 Inputs__Slave 11A, DI1))
UINT32
RO
0xF600:52, 1
1A40:53
SubIndex 083
83. PDO Mapping entry (object 0xF600 (ASI Digital In-
puts), entry 0x53 (Slave 11 Inputs__Slave 11A, DI2))
UINT32
RO
0xF600:53, 1
1A40:54
SubIndex 084
84. PDO Mapping entry (object 0xF600 (ASI Digital In-
puts), entry 0x54 (Slave 11 Inputs__Slave 11A, DI3))
UINT32
RO
0xF600:54, 1
1A40:55
SubIndex 085
85. PDO Mapping entry (object 0xF600 (ASI Digital In-
puts), entry 0x55 (Slave 11 Inputs__Slave 11B, DI0))
UINT32
RO
0xF600:55, 1
1A40:56
SubIndex 086
86. PDO Mapping entry (object 0xF600 (ASI Digital In-
puts), entry 0x56 (Slave 11 Inputs__Slave 11B, DI1))
UINT32
RO
0xF600:56, 1
1A40:57
SubIndex 087
87. PDO Mapping entry (object 0xF600 (ASI Digital In-
puts), entry 0x57 (Slave 11 Inputs__Slave 11B, DI2))
UINT32
RO
0xF600:57, 1
1A40:58
SubIndex 088
88. PDO Mapping entry (object 0xF600 (ASI Digital In-
puts), entry 0x58 (Slave 11 Inputs__Slave 11B, DI3))
UINT32
RO
0xF600:58, 1
1A40:59
SubIndex 089
89. PDO Mapping entry (object 0xF600 (ASI Digital In-
puts), entry 0x59 (Slave 12 Inputs__Slave 12A, DI0))
UINT32
RO
0xF600:59, 1
1A40:5A
SubIndex 090
90. PDO Mapping entry (object 0xF600 (ASI Digital In-
puts), entry 0x5A (Slave 12 Inputs__Slave 12A, DI1))
UINT32
RO
0xF600:5A, 1
1A40:5B
SubIndex 091
91. PDO Mapping entry (object 0xF600 (ASI Digital In-
puts), entry 0x5B (Slave 12 Inputs__Slave 12A, DI2))
UINT32
RO
0xF600:5B, 1
1A40:5C
SubIndex 092
92. PDO Mapping entry (object 0xF600 (ASI Digital In-
puts), entry 0x5C (Slave 12 Inputs__Slave 12A, DI3))
UINT32
RO
0xF600:5C, 1
1A40:5D
SubIndex 093
93. PDO Mapping entry (object 0xF600 (ASI Digital In-
puts), entry 0x5D (Slave 12 Inputs__Slave 12B, DI0))
UINT32
RO
0xF600:5D, 1
1A40:5E
SubIndex 094
94. PDO Mapping entry (object 0xF600 (ASI Digital In-
puts), entry 0x5E (Slave 12 Inputs__Slave 12B, DI1))
UINT32
RO
0xF600:5E, 1
1A40:5F
SubIndex 095
95. PDO Mapping entry (object 0xF600 (ASI Digital In-
puts), entry 0x5F (Slave 12 Inputs__Slave 12B, DI2))
UINT32
RO
0xF600:5F, 1