background image

 

Installation 

 

3.4  Connecting the Industrial PC 

 

The mains plug must be disconnected 

 

Attention 

The power supply plug must be withdrawn! 

Please read the documentation for the external devices prior to connecting them! 

During thunderstorms, plug connector must neither be inserted nor removed! 

When disconnecting a plug connector, always handle it at the plug. Do not pull the cable!

 

3.4.1 Connecting cables 

The connections are located at the top side of the Industrial PC and are documented in the 

Product 

Description

 chapter. 

When connecting the cables to the Industrial PC, proceed according to the following sequence: 

• 

Switch off all the devices that are to be connected. 

• 

Disconnect all the devices that are to be connected from the power supply. 

• 

Connect all the cables between the Industrial PC and to the devices that are to be connected. 

• 

Connect all data transfer cables (if present) to the appropriate plug-in receptacles of the data/ 
telecommunication networks. 

• 

Reconnect all devices to the power supply. 

 

C6670-0010 

19 

Summary of Contents for C6670-0010

Page 1: ...Installation and Operating instructions for C6670 0010 Control Cabinet Industrial Server Version 1 2 Date 2018 11 23...

Page 2: ......

Page 3: ...2 2 Appropriate Use 9 2 3 Opening the Housing 9 2 4 Access to the battery 11 2 5 Access to the fans 12 2 5 1 Replacing the fans in the area of the interfaces 12 2 5 2 Exchanging the fan cartridge 13...

Page 4: ...ff 20 4 1 1 Switch on 20 4 1 2 Shutting down and switching off 20 4 1 3 First switching on and driver installation 20 4 2 Servicing and maintenance 21 4 2 1 Cleaning of the Industrial PC 21 4 2 2 Main...

Page 5: ...and XTS are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could viol...

Page 6: ...als Risk of injury WARNING If you do not adhere the safety advise adjoining this symbol there is danger to life and health of individuals Hazard to individuals CAUTION If you do not adhere the safety...

Page 7: ...the fieldbus connection plug uncouples the PC optional Items of equipment that have been switched off must be secured against being switched on again The Industrial PC s power supply unit must be sup...

Page 8: ...ing Attention The operator is responsible for ensuring that only trained electrical staff opens the housing of the Industrial PC 1 4 1 National regulations Depending on the type of machine and plant i...

Page 9: ...available for several camera interface cards for video evaluation All connections of the Industrial Server face upwards so that the connecting cables can be taken directly to the wiring channel The s...

Page 10: ...Server for control cabinet installation all slots for full size plug in cards 2 removable frames for hard disks drives and plug in cards easily accessible all connectors on the top detailed PC config...

Page 11: ...Industrial Server must not be used where there is a risk of explosion 2 3 Opening the Housing Top view of the C6670 0010 The housing cover is locked by a latch After pressing the key 1 the cover can b...

Page 12: ...e taken off completely so providing access to the components The reassembly of the cover takes place in reverse order Ensure that the cover engages into the slides 2 Removing the card holder card hold...

Page 13: ...the housing 2 4 Access to the battery Removing the cover allows access to the battery Danger of Explosion WARNING The battery is a CR2032 type nominal voltage 3 0 V from e g Panasonic or Sanyo Replac...

Page 14: ...fans in the area of the interfaces Identical fan type Attention Replace the fans only with the identical type or an alternative type approved by Beckhoff Remove the housing cover Note For exchanging...

Page 15: ...hoff For exchanging the fan cartridge 1 first solve the knurled screw 2 Opening the fan cartridge 2 1 The cartridge can then be folded down and taken out Removing the fan Disconnect the supply cable f...

Page 16: ...rted The power delivery is each limited to 900 mA 2 6 3 USB interfaces USB1 USB2 X110 X111 The two USB interfaces X110 X111 are used for connecting peripheral devices with USB connection USB2 0 standa...

Page 17: ...video signal DVI D standard is supported The power delivery is limited to 1000 mA 2 6 8 Additional plug in cards optional There is a type plate on the front cover of the Industrial Server which provi...

Page 18: ...condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a delay time of approximately 12 hours mus...

Page 19: ...the PC must be provided The clearance above and below the housing must be at least 5 cm in order to ensure adequate ventilation of the PC Avoid extreme environmental conditions Attention Extreme envir...

Page 20: ...e you use the provided cable with inlet connector for non heating apparatus to connect the Industrial PC to the power supply Minimum temperature rating of supply cables should be 80 C 3 3 4 Power cord...

Page 21: ...nnections are located at the top side of the Industrial PC and are documented in the Product Description chapter When connecting the cables to the Industrial PC proceed according to the following sequ...

Page 22: ...destroyed Control software typically writes something to the memory drive every few seconds so that the probability of causing damage by switching off while the software is running is very high Switc...

Page 23: ...an alternative type recommended by the manufacturer Notice correct polarity Handling of Lithium Batteries WARNING Lithium Batteries should not be recharged exposed to fire opened and they should be pr...

Page 24: ...Call Beckhoff Service Computer boots software starts but control does not operate correctly Cause of the fault is either in the software or in parts of the plant outside the Industrial PC Call the ma...

Page 25: ...mensions 6 Assembly dimensions Industrial Server C6670 0010 Notice mounting orientation Attention The assembly of the unit must take place with the orientation diagrammed here All dimensions in mm C66...

Page 26: ...Assembly dimensions Notice mounting orientation Attention The assembly of the unit must take place with the orientation diagrammed here All dimensions in mm 24 C6670 0010...

Page 27: ...istance Sinusoidal vibration EN 60068 2 6 10 to 58 Hz 0 035 mm 58 to 500 Hz 0 5 G 5 m s2 Shock resistance Shock EN 60068 2 27 5 G 50 m s2 duration 30 ms EMC compatibility Resistance to interference co...

Page 28: ...KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 E mail info beckhoff de Web http www beckhoff de Beckhoff Support Support offers you comprehensive technical assista...

Page 29: ...generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this e...